Filter Replacement - Dustcontrol DC 5900H Asbest Traduction Des Instructions De Service D'origine

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 37
7.
Clean the maintenance area in advance.
8.
Use appropriate personal protective equipment.
9.
The cyclone filter cartridge must be replaced when necessary, but at least once a year. Only use original filters, see
Consumables.
WARNING
Do not reuse the filter after it has been removed from the machine.
The fine filter must be changed at least once a year. The HEPA filter must be replaced after approx. 300 hours of operation. Wear
a protective mask when changing the filter. Only use original filters. Release and lift off the cover. To prevent leakage of dust,
place a plastic bag over the cyclone and remove the filter cartridge. Clean the filter plate. Fit the new filter.
1
The HEPA filter is removed by opening the cover and detaching the cartridge. By gently tilting the detached motor head away
from the cyclone, a lateral pressure occurs on the HEPA filter cartridge that is attached to the motor. If necessary, repeat the
procedure until the HEPA filter falls into the fine filter cartridge. The HEPA filter and the fine filter can then be discarded. The new
filter cartridge is placed in the fine filter and is sealed when you carefully fit the cover.
The vacuum unit has an extremely long service life and requires no maintenance. The seals must be checked after approximately
1,000 hours of operation. These parts must be replaced if wear is detected.

Filter replacement

Filter replacement may only be performed by trained personnel. Use a protective mask and suitable equipment.
1.
Remove the screw.
2
3
DC 5900H, Art.nr. 94380-B
4
17

Publicité

Table des Matières
loading