Assembly; Maintenance; Asme Safety Valve; Drain Tank - Campbell Hausfeld HU350899 Instructions D'utilisation Et Manuel De Pièces

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

Operating Instructions and Parts Manual

Assembly

HANDLE ASSEMBLY (Figure 1)
1. Place ends of handle around tank and into the mounting
pipe. Align holes in handle to holes in mounting pipe.
2. Assemble two (2) screws (from parts package) through
holes in mounting pipe and handle. Tighten screws.
Never use the handle to lift the unit
completely off the ground. Only use the handle to lift one end
so the wheels may be used to move the unit.
Figure 1 - Handle Assembly
WHEEL ASSEMBLY (Figure 3)
Wheel assembly kit includes:
- 2 wheels *
- 2 axle bolts *
- 2 washers *
- 2 nuts *
The items marked with an asterisk (*) were shipped loose with
the unit.
1. Wheel has an offset hub. Place wheel insert into center of
hub. With offset hub facing axle iron, assemble axle bolt
through washer and then holes in wheel and axle iron.
2. Place lock washer on axle bolt. Then tighten nut securely
to threaded part of axle bolt.
3. Repeat procedure with other side.
Nut
Figure 3 - Wheel Assembly
www.campbellhausfeld.com
Screws
Washer
Wheel
Axle Bolt

Maintenance

Disconnect, tag and lock out
power source, then release all pressure from
the system before attempting to install, service,
relocate or perform any maintenance.
Check compressor often for any visible problems and follow
maintenance procedures each time compressor is used.

ASME SAFETY VALVE

Do not remove or attempt to adjust the
safety valve!
Check the safety valve by performing the following steps:
1. Plug the compressor in and run until shut off pressure is
reached.
2. Wearing safety glasses, pull the ring on the safety valve to
release pressure from compressor tank. The safety valve
should remain open. Use your other hand to defl ect fast-
moving air from being directed toward your face.
3. The safety valve should automatically close at
approximately 40 psi - 50 psi. If the safety valve does not
allow air to be released when you pull on the ring and
remain out, or if it does not close automatically, it MUST
be replaced.
Figure 7
Safety valve must be
cannot be actuated or it leaks air after ring
is released.

DRAIN TANK

1. Turn compressor off and release pressure from system. (To
release pressure from system, pull ring on ASME safety
valve. Deflect escaping air by shielding valve with one
hand as you pull ring with other hand.) Pull ring until tank
is empty.
A large amount of fast moving air will be
released when the safety valve is opened
with pressure in the tank. Wear ANSI approved Z87.1 safety
glasses.
2. Drain moisture from tank by opening drain valve
underneath tank. Tilt tank to remove all moisture.
3. Clean dust and dirt from tank, air lines and pump cover
while compressor is still OFF.
INTAKE AIR FILTER MAINTENANCE
Removal, Inspection and Replacement (Figure 8).
The intake filter element should be removed and checked
periodically. A clogged intake filter can decrease compressor
performance and cause the compressor to overheat.
6
replaced if it

Publicité

Table des Matières
loading

Table des Matières