Télécharger Imprimer la page

Publicité

Les langues disponibles

Les langues disponibles

Liens rapides

See warranty on page 8 for important information about commercial use of this product.
operating instructions
Please read and save these instructions. Read carefully before attempting to assemble, install, operate or maintain the product described.
Protect yourself and others by observing all safety information. Failure to comply with instructions could result in personal injury and/or
property damage! Retain instructions for future reference.
Description
Portable oilless air compressors are for
home and workshop use. Cleaning or
replacement of the inlet filter on all
models and draining moisture from the
air receivers are required maintenance.
Safety Guidelines
This manual contains information
that is very important to know
and understand. This information
is provided for SAFETY and to
PREVENT EQUIPMENT PROBLEMS.
To help recognize this information,
observe the following symbols.
Danger indicates
an imminently
hazardous situation which, if not
avoided, WILL result in death or serious
injury.
Warning indicates
a potentially
hazardous situation which, if not
avoided, COULD result in death or
serious injury.
Caution indicates
a potentially
hazardous situation which, if not
avoided, MAY result in minor or
moderate injury.
Notice indicates
important
information, that if not followed, may
cause damage to equipment.
Unpacking
When unpacking unit, inspect carefully
for any damage that may have occurred
during transit. Make sure any loose
fittings, bolts, etc., are tightened before
putting unit into service. In case of
questions, damaged or missing parts,
please call 1-800-543-6400 for customer
assistance. Have the serial number,
model number, and parts list (with
missing parts circled) before calling.
© 2010 Campbell Hausfeld/Scott Fetzer
Record the Model No., Serial No. and
date of purchase in the space below.
Model No.
Serial No.
Date of purchase _________________
Retain these numbers for future
STOP!
shipping, handling or use. Damage may
result in bursting and cause injury or
property damage.
REMINDER: Keep your dated proof of purchase for warranty purposes!
Attach it to this manual or file it for safekeeping.
For parts, product & service information,
visit www.chpower.com
hG3000 Series, hJ3001 Series, hJ3002 Series
200 pSi portable aSMe
______________________
______________________
reference.
Do not retUrn
the proDUct to
the retailer!
Do not operate unit
if damaged during
air compressors
Breathable Air Warning
this compressor / pump is not
equipped and should not be
used "as is" to supply breathing
quality air. For any application of
air for human consumption, the
air compressor / pump will need
to be fitted with suitable in-line
safety and alarm equipment.
this additional equipment is
necessary to properly filter
and purify the air to meet
minimal specifications for Grade
D breathing as described in
compressed Gas association
commodity Specification G
7.1 - 1966, oSha 29 cFr 1910.
134, and / or canadian Standards
associations (cSa).
DiSclaiMer oF warrantieS
in the event the compressor is
used for the purpose of breathing
air application and proper in-line
safety and alarm equipment is
not simultaneously used, existing
warranties shall be voided, and
the campbell hausfeld disclaims
any liability whatsoever for any
loss, personal injury or damage.
reaD & Follow all inStrUctionS
Save theSe inStrUctionS
Do not DiScarD
IN634100AV 7/10

Publicité

loading

Sommaire des Matières pour Campbell Hausfeld HG3000 Serie

  • Page 1 Do not DiScarD REMINDER: Keep your dated proof of purchase for warranty purposes! Attach it to this manual or file it for safekeeping. © 2010 Campbell Hausfeld/Scott Fetzer For parts, product & service information, IN634100AV 7/10 visit www.chpower.com...
  • Page 2 Operating Instructions General Safety 13. Guard all moving parts; keep visitors 3. Do not stand on or use the pump or away. Never allow children in work unit as a handhold. caliFornia propoSition 65 area. 4. Do not exceed pressure rating of This product or its 14.
  • Page 3 hG3000 Series, hJ3001 Series, hJ3002 Series General Safety assembly Wheel (continued) aSSeMblY toolS reqUireD Washer Tools (not provided) for assembly: 22. Drain tanks of moisture after each day’s use. If unit will not be used (1) #2 Phillips screwdriver for a while, it is best to leave drain Bolt (2) adjustable wrenches cock open until such time as it is to...
  • Page 4 Operating Instructions introduction installation pressure Gauges - These gauges will show air pressure in the compressor pressure Switch - ON/OFF Switch - In tank and at the compressor outlet. location the ON position, the compressor shuts It is extremely important to install the outlet pressure Gauge - Will show off automatically when tank pressure compressor in a clean, well ventilated...
  • Page 5 hG3000 Series, hJ3001 Series, hJ3002 Series installation 3. If above conditions cannot be met Check with a qualified electrician (continued) or if nuisance tripping of current or serviceman when the grounding wirinG protection device occurs, it may be instructions are not completely 1.
  • Page 6 Operating Instructions operation continuously, the compressor will cycle 2. Pull ring on safety valve and allow on and off automatically. it to snap back to normal position beFore FirSt Start-Up (Figure 5). In the OFF position, the pressure switch break-in proceDUre Safety valve must be cannot function and the compressor (Complete this procedure before using...
  • Page 7 hG3000 Series, hJ3001 Series, hJ3002 Series Maintenance 2. Wrong gauge wire or length of StoraGe (continued) extension cord. 1. When not in use, hose and This compressor is compressor should be stored in a 3. Clogged air filter. equipped with a cool dry place.
  • Page 8 2. WHO GIVES THIS WARRANTY (WARRANTOR): Campbell Hausfeld / Scott Fetzer Company, 100 Production Drive, Harrison, Ohio, 45030, Telephone: (800) 543-6400. 3. WHO RECEIVES THIS WARRANTY (PURCHASER): The original purchaser (other than for purposes of resale) of the Campbell Hausfeld compressor.
  • Page 9 MarchanD ! ne paS Jeter manquantes, appeler le MÉMento: Gardez votre preuve datée d'achat à fin de la garantie! Joignez-la à ce manuel ou classez-la dans un dossier pour plus de sécurité. © 2010 Campbell Hausfeld/Scott Fetzer IN634100AV 7/10 9 Fr...
  • Page 10 Instructions d’Utilisation Généralités Sur la monter, démonter ou de faire 11. Les moteurs électriques doivent être fonctionner votre système. mis à la terre correctement. Voir Sécurité les instructions de mise à la terre et 2. Utiliser des lunettes de l’information concernant les cordons propoSition 65 caliFornie sécurité...
  • Page 11 Série Série Série hG3000, hJ3001, hJ3002 Généralités Sur la 2. Ne pas pulvériser dans l’endroit 2. Placer la clé ajustable sur le boulon d’une flamme ni dans un endroit d'essieu. Utiliser une deuxième clé Sécurité (Suite) ajustable, bien resserrer l'écrou à la où...
  • Page 12 Instructions d’Utilisation installation introduction Manomètre(s) - Ces manomètres indiquent la pression d’air dans le enDroit Manostat - Interrupteur ON/OFF – Dans réservoir du compresseur et à la sortie Il est très important d’installer le la position ON, le compresseur se coupe du compresseur.
  • Page 13 Série Série Série hG3000, hJ3001, hJ3002 installation (Suite) inStrUctionS De MiSe À la terre mis à la terre. Ne pas modifier la fiche fournie si elle n'entre pas correctement Ce produit doit être mis à la terre. inStallation De FilS dans la prise, faire installer une prise Dans l’évenement d’un court-circuit, 1.
  • Page 14 Instructions d’Utilisation Functionnement 7. Tourner le bouton du régulateur l’hUMiDitÉ DanS l’air complètement vers la droite, dans avant le preMier DÉMarraGe coMpriMÉ le sens des aiguilles d'une montre procÉDUre De rôDaGe L’humidité dans l’air comprimé forme jusqu'à la pression voulue pour Cette procédure doit être terminée des goutelettes en arrivant de la l'outil utilisé.
  • Page 15 Série Série Série hG3000, hJ3001, hJ3002 entretien 3. Quotidiennement avec le GraiSSaGe compresseur hors circuit : Ce compresseur est de type “sans huile” SoUpape De SÛretÉ aSMe Dépressuriser le système avant et n’exige pas de graissage. Ne jamais enlever de drainer le réservoir. Drainer ou essayer d’ajuster protecteUr De SUrcharGe l'humidité...
  • Page 16 Instructions d’Utilisation Guide De Dépannage Symptôme cause(s) possible(s) Mesures correctives Compresseur ne 1. Perte de puissance ou surchauffage 1. Vérifier l’usage correct des cordons prolongateurs (voir fonctionne pas CORDONS PROLONGATEURS, page 13) 2. Manque de puissance électrique 2. Modèle branché? Vérifier le fusible/disjoncteur ou surcharge du moteur 3.
  • Page 17 Série Série Série hG3000, hJ3001, hJ3002 notes 17 Fr...
  • Page 18 9. RESPONSABILITÉS DE L’ACHETEUR AUX TERMES DE CETTE GARANTIE: A. Fournir une preuve d’achat datée et un état d’entretien. B. La livraison ou expédition des compresseurs portatifs ou des pièces détachées au Centre De Service Autorisé Campbell Hausfeld. Taux de frais, si applicables, sont la responsabilité de l’acheteur.
  • Page 19 MarchanD! 1-800-543-6400 por asistencia al cliente. no laS DeSeche recorDatorio: ¡Guarde su comprobante de compra con fecha para fines de la garantía! adjúntela a este manual o archívela en lugar seguro. © 2010 Campbell Hausfeld/Scott Fetzer IN634100AV 7/10 19 Sp...
  • Page 20 Manual de Instrucciones Generales de 1. Lea con cuidado todos 9. Siga todos los códigos de los manuales incluídos electricidad y seguridad locales y Seguridad con este producto antes nacionales al igual que las medidas MANUAL de tratar de ensamblar, de seguridad laboral.

Ce manuel est également adapté pour:

Hj3001 serieHj3002 serie