Publicité

Les langues disponibles

Les langues disponibles

Liens rapides

See Warranty on page 8 for important information about commercial use of this product.
Operating Instructions
Please read and save these instructions. Read carefully before attempting to assemble, install, operate or maintain the
product described. Protect yourself and others by observing all safety information. Failure to comply with instructions
could result in personal injury and/or property damage! Retain instructions for future reference.
RegisteR youR pRoduct online now!
Description
Portable oilless air compressors are for
home and workshop use. Cleaning or
replacement of the inlet filter on all
models and draining moisture from the
air receivers are required maintenance.
Safety Guidelines
This manual contains information
that is very important to know
and understand. This information
is provided for SAFETY and to
PREVENT EQUIPMENT PROBLEMS.
To help recognize this information,
observe the following symbols.
Danger indicates
an imminently
hazardous situation which, if not
avoided, WILL result in death or
serious injury.
Warning indicates
a potentially
hazardous situation which, if not
avoided, COULD result in death or
serious injury.
Caution indicates
a potentially
hazardous situation which, if not
avoided, MAY result in minor or
moderate injury.
Notice indicates
important
information, that if not followed,
may cause damage to equipment.
Unpacking
When unpacking unit, inspect carefully
for any damage that may have occurred
during transit. Make sure any loose
fittings, bolts, etc., are tightened before
putting unit into service.
© 2012 Campbell Hausfeld/Scott Fetzer
Record the Model No., Serial No. and
date of purchase in the space below.
Model No.
Serial No.
Date of purchase _________________
Retain these numbers for
In case of questions, damaged or missing
parts, please call 1-800-543-6400 for
customer assistance. Have the serial
number, model number, and parts
list (with missing parts circled) before
calling.
STOP!
during shipping, handling or use.
Damage may result in bursting and
cause injury or property damage.
REMINDER: Keep your dated proof of purchase for warranty purposes!
Attach it to this manual or file it for safekeeping.
For parts, product & service information,
visit www.chpower.com
http://www.chpower.net/reg
______________________
______________________
future reference.
DO NOT RETURN
THE pRODUCT TO
THE RETAILER!
Do not operate
unit if damaged
200 pSI portable
Air Compressor
Breathable Air Warning
This compressor / pump is not
equipped and should not be
used "as is" to supply breathing
quality air. For any application of
air for human consumption, the
air compressor / pump will need
to be fitted with suitable in-line
safety and alarm equipment.
This additional equipment is
necessary to properly filter
and purify the air to meet
minimal specifications for Grade
D breathing as described in
Compressed Gas Association
Commodity Specification G
7.1 - 1966, OSHA 29 CFR 1910.
134, and / or Canadian Standards
Associations (CSA).
DISCLAIMER OF WARRANTIES
In the event the compressor is
used for the purpose of breathing
air application and proper in-line
safety and alarm equipment is
not simultaneously used, existing
warranties shall be voided, and
the Campbell Hausfeld disclaims
any liability whatsoever for any
loss, personal injury or damage.
Risk of Bursting! This
compressor is designed
to provide air pressure
up to 200 psi. Most attachments
are designed to operate at a
maximum pressure of less than 125
psi. DO NOT adjust the regulator
to result in output pressure
greater than the marked maximum
pressure of the attachment.
READ & FOLLOW ALL INSTRUCTIONS
SAvE THESE INSTRUCTIONS
DO NOT DISCARD
HG3007
IN639200AV 8/12

Publicité

Table des Matières
loading

Sommaire des Matières pour Campbell Hausfeld HG3007

  • Page 1 SAvE THESE INSTRUCTIONS DO NOT DISCARD REMINDER: Keep your dated proof of purchase for warranty purposes! Attach it to this manual or file it for safekeeping. For parts, product & service information, © 2012 Campbell Hausfeld/Scott Fetzer IN639200AV 8/12 visit www.chpower.com...
  • Page 2: General Safety Information

    Operating Instructions General Safety 12. Always disconnect power source 2. Wear safety glasses and before working on or near a motor, use hearing protection CALIFORNIA pROpOSITION 65 or its connected load. If power when operating the This product or its disconnect point is out-of-sight, lock pump or unit.
  • Page 3: Spraying Precautions

    HG3007 General Safety Check valve - A one-way valve 7. Use a face mask/ respirator when that allows air to enter the tank, but (Continued) spraying and spray in a prevents air in the tank from flowing well ventilated area to back into the compressor pump.
  • Page 4 Operating Instructions Installation NOTE: 120 volt, compressor can be This product is for use on a nominal operated on a 120 volt, 15 amp circuit 120V circuit and has a grounding plug LOCATION under the following conditions: similar to the plug illustrated in It is extremely important to install the Figure 2.
  • Page 5: Drain Tank

    HG3007 Operation Maintenance Safety valve must be replaced if it BEFORE FIRST START-Up cannot be actuated or it leaks air after ring is released. BREAk-IN pROCEDURE Disconnect power (Complete this procedure before using DRAIN TANk source then release compressor for the first time. Once...
  • Page 6: Thermal Overload Protector

    Operating Instructions Maintenance END OF OpERATION/STORAGE (Continued) 1. Turn ON/OFF switch to OFF position. THERMAL OvERLOAD pROTECTOR 2. Unplug power cord from wall outlet Turn off the pressure switch or unplug and wrap around handle to prevent compressor for 20 minutes and allow it damage when not in use.
  • Page 7: Troubleshooting Chart

    HG3007 Troubleshooting Chart Symptom possible Cause(s) Corrective Action Compressor will 1. No electrical power 1. Plugged in? Switch on? Check fuse / breaker. not run 2. Breaker open 2. Reset, determine cause of problem 3. Pressure switch bad 3. Replace 4.
  • Page 8 8. RESPONSIBILITIES OF PURCHASER UNDER THIS WARRANTY: A. Provide dated proof of purchase and maintenance records. B. Portable compressors or components must be delivered or shipped to the nearest Campbell Hausfeld Authorized Service Center. Freight costs, if any, must be borne by the purchaser.
  • Page 9 NE pAS JETER MÉMENTO: Gardez votre preuve datée d'achat à fin de la garantie! Joignez-la à ce manuel ou classez-la dans un dossier pour plus de sécurité. © 2012 Campbell Hausfeld/Scott Fetzer IN639200AV 8/12 9 Fr...
  • Page 10: Généralités Sur La Sécurité

    Instructions d’Utilisation Généralités Sur La 1. Lire attentivement 9. Suivre toutes les codes locaux tous les manuels d’électicité et de sécurité, ainsi que Sécurité d’instructions pour le National Electrical Code (NEC) et MANUEL chaque pièce détachée le Occupational Safety and Health pROpOSITION 65 CALIFORNIE Ce produit ou son avant d’esssayer de...
  • Page 11: Généralités Sur La Sécurité (Suite)

    HG3007 Généralités Sur La 23. Vérifier le réservoir 5. Suivre les instructions du fabriquant quotidiennement pour la pendant la pulvérisation ou le Sécurité (Suite) rouille, trous d’épingle ou autres nettoyage avec des solvants ou imperfections qui peuvent avoir produits chimiques toxiques.
  • Page 12: Installation Électrique

    Instructions d’Utilisation Introduction Installation Sortie d'Air - Un raccord rapide conçu pour fonctionner de pair avec une fiche ENDROIT Manostat - Interrupteur ON/OFF – à raccordement rapide pour joindre Il est très important d’installer le Dans la position ON, le compresseur rapidement et facilement un outil compresseur dans un endroit propre se coupe automatiquement quand...
  • Page 13: Installation (Suite)

    HG3007 Installation (Suite) Functionnement dans la prise, faire installer une prise convenable par un électricien qualifié. AvANT LE pREMIER DÉMARRAGE REMARqUE: Les modèles de 120 volts, Ce produit est conçu pour être utilisé pROCÉDURE DE RôDAGE compresseur peuvent fonctionner sur avec un circuit nominal de 120 volts et Cette procédure doit être terminée...
  • Page 14: Entretien

    Instructions d’Utilisation Functionnement pas être nettoyés. Placer le filtre dans la base du carter et remplacer le (Suite) couvercle. 6. Fixer le mandrin de pneu ou l'outil à GRAISSAGE l'extrémité du tuyau. Figure 3 Ce modèle “sans huile” n’exige pas de 7.
  • Page 15: Guide De Dépannage

    HG3007 Guide De Dépannage Symptôme Cause(s) possible(s) Mesures Correctives Le compresseur 1. Manque de puissance électrique 1. Modèle branché? L’interrupteur est-il sur la position ON? Vérifier le ne fonctionne fusible/disjoncteur 2. Disjoncteur déclenché 2. Rajuster et trouver la source du problème 3.
  • Page 16: Garantie Limitée

    2. GARANTIE ACCORDÉE PAR (GARANT): Campbell Hausfeld/Scott Fetzer Company, 100 Production Drive, Harrison, Ohio, 45030, Téléphone: (800) 543-6400. 3. BÉNÉFICIAIRE DE CETTE GARANTIE (ACHETEUR): L’acheteur original (sauf en cas de revente) du produit Campbell Hausfeld. 4. PRODUITS COUVERTS PAR CETTE GARANTIE: Ce compresseur d’air Campbell Hausfeld.
  • Page 17: Compresor De Aire Portátiles De 13,79 Bar

    GUARDE ESTAS INSTRUCCIONES NO LAS DESECHE RECORDATORIO: ¡Guarde su comprobante de compra con fecha para fines de la garantía! Adjúntela a este manual o archívela en lugar seguro. © 2012 Campbell Hausfeld/Scott Fetzer IN639200AV 8/12 17 Sp...
  • Page 18: Informaciones Generales De Seguridad

    Manual de Instrucciones Generales de Todos los trabajos de electricidad Seguridad los debe hacer un electricista Mantenga los dedos calificado (con licencia o alejados del scompresor pROpOSICIÓN DE CALIFORNIA 65 certificación). En los circuitos cuando esté funcionando; Este producto o conectados adecuadamente los las piezas en movimiento o su cable de...
  • Page 19 HG3007 Generales de 22. Drene el tanque diariamente. Si 4. Nunca rocíe la pintura y otros no piensa usar el compresor por materiales, directamente hacia el Seguridad (Continuación) un tiempo, es preferible que deje compresor. Coloque el compresor la llave de salida abierta hasta que lo más lejos posible del área...
  • Page 20: Instalación Eléctrica

    Manual de Instrucciones Introducción Instalación Salida de air - Un acoplador de conexión rápida que está diseñado COLOCACIÓN presostato - Presostato ON/OFF - para trabajar en combinación con un Es de suma importancia instalar el En la posición ON (encindido) el conector rápido para conectar rápida compresor en un llugar limpio y bien compresor se apaga automáticamente...
  • Page 21 HG3007 Instalación de forma adecuada. No modifique el inmediatamente superior. Cuanto más (Continuación) bajo sea el número del calibre, más enchufe que se proporciona, si no lo NOTA: Las unidades de 120 voltios, grueso será el cable. puede conectar al tomacorriente, haga compresor pueden utilizar en circuitos que un técnico calificado instale el...
  • Page 22 Manual de Instrucciones Funcionamiento Revise la válvula de seguridad siguiendo Reemplace los filtros de aire que no se los siguientes pasos: puedan limpiar. Coloque el filtro dentro (Continuación) de la base y tápelo. 1. Enchufe el compresor y hágalo 6. Conecte la boquilla para inflar funcionar hasta que se alcance LUBRICACION neumáticos u otra herramienta al...
  • Page 23: Guía De Diagnóstico De Averías

    HG3007 Guía de Diagnóstico de Averías problema posible(s) Causa(s) Acción a Tomar El compressor no 1. No hay energía eléctrica 1. ¿Está conectado? ¿Está prendido el interruptor? Chequée el fusible/ funciona cortacircuito 2. Cortacircuito desconectado 2. Conéctelo, determine la causa del problema 3.
  • Page 24: Garantía Limitada

    A. Suministrar prueba fechada de compra y la historia de mantenimiento del producto. B. Entregar o enviar los compresores de aire portátiles o componentes lal Centro de Servicio autorizado Campbell Hausfeld más cercano. Los gastos de flete, de haberlos, deben ser pagados por el comprador.

Table des Matières