Operation

Welding parameters

• Set potentiometer for welding speed (19) to required value.
• Set potentiometer for air flow (20) to required value.
• Set potentiometer for air temperature (21) to required value.
• The pressure derives from the actual weight of the automatic hot air welding machine. Use additional weight if
necessary.
(17) Main switch
Welding speed
Air flow
(18) Drive switch
• Assembling additional weight
– Attach additional weight holder (29) to the UNIPLAN E tool
by means of cylindrical head screw M8x20 (28).
– Put additional weight (30) into additional weight holder
(29).

Welding process

• Swivel hot air blower (3) up to the stop using swivel lever (22). The welding process starts automatically via
automatic drive.
• If necessary, the tool can be started manually by means of the drive switch (18).
• Check welding process. Adjust welding parameters using potentiometers (19), (20) and (21) if necessary.
• When welding has finished, swing hot air blower (3) to the stop by means of swivel lever (22). Welding process
stops automatically.
• After completing welding work, set potentiometer for air temperature (21) to zero so that the hot air blower (3)
cools down.
•Switch off tool at the main switch (17).
• Disconnect tool from the mains.
Speed m/ft
Temperature
Air-Vol %
ON
Speed
Air-Vol %
Display (15)
Temperatur ACTUAL- value
Temperatur SET- value
Potentiometer for welding speed (19)
Potentiometer for air flow (20)
Potentiometer for air temperature (21)
Temperature
Accessory additional weight
29
30
Leister UNIPLAN E