Safety Technique
SAFEMASTER STS/K
Safety Switch- And Key Interlock System
Basic Unit SX01BM/K
Presentation in the deactivated condition:
Key and actuator removed

Product Description

Switch with separate actuator and forced key removal
When the key is removed, the contacts switch and the actuator is released.
For the key exchange and duplication with mechanical securing of
separating guards such as safety gates and hoods in machine and plant
engineering.
All technical data in this list relate to the state at the moment of edition. We reserve the right for
technical improvements and changes at any time.
STS/K-System Benefits
• EU-Test certificate according to the directive 2006/42/EG, annex IX
• For safety applications up to PLe / Cat. 4 acc. to DIN EN ISO 13849-1
• Modular and expandable system
• Rugged composite version of stainless steel and FRP design
• Wireless mechanical safeguarding
• Combines the benefits of safety switch, solenoid locking and
key transfer in a single system
• Easy installation through comprehensive accessories
• Protection against lock-in
• Coding level low, medium, high according to DIN EN ISO 14119:2014-03
Features
The unit is particularly suitable for applications with:
• Full body access (lock-in danger)
• Optional key removal
• Several secured entries
• Rugged ambient conditions
• This units are also available in stainless steel

Approvals and Markings

Function

The SX01BM/K version offers increased stability of the actuator module.
It is also available in accordance with EN ISO14119:2013 with actuators
for low and medium coding levels.
The key can be used as part of a key transfer system or as a personal
key, i.e. as protection against confinement and unexpected restart.
Multiple keys make it possible to operate several units in the system or
to protect several people. For this purpose, the SX01BM/K unit can also
be extended above the actuator module with additional key modules. By
using personal key normally no escape release (ISO TS19837:2017) is
required.
Both versions can optionally be equipped with padlock modules and
manual unlocking. Switch modules with disable function have the
designation SV module.This unit can be connected to the SAFEMASTER
STS option module, which contains command functions and is designed
for wiring cross sections up to 1.5 mm
19
.
2
SAFEMASTER STS/K SX01BM/K / 22.06.20 en / 246A