Electrical connections
(N.O.) contact. for command device
(Transponder or card reader with
R700 board).
(N.O.) contact. for command
device (keypad selector with
R800 board).
Attenzione! Le schede e la
memory roll vanno inserite in assenza
di tenzione.
L-N
230 V AC powered, 50 / 60 Hz frequency
M-N
24 V DC motor
+ ENC2 - Encoder
10-11 24 V AC powering accessories (40 W max.)
10-E
Movement Flasher (contact rated for: 24 V - 25 W max.)
10-5
Gate open warning light (Contact rated for: 24 V - 3 W max).
2-CX..CY Re-open during closing (N.C.) socket, re-close during opening, partial
stop or stand-by obstacle
The data and information reported in this installation manual are susceptible to change at any time and without obligation on CAME cancelli automatici s.p.a. to notify users.
M E
C A
R700
R800
Red
Black
White
Blue
1-2
Stop button (N.C. contact.)
2-3
Opening device (N.O. contact)
2-3P
Device for partial or pedestrian opening (N.O. contact).
2-4
Closing device (N.O. contact)
2-7
Command device (N.O. contact). Commands for opening and closing
the gate, see feature F 7.
Antenna connection
AF radio
frequency
board