3.2 Emergency information

4 Putting into operation

4.1 Equipping the torch
®
ABIMIG
401/501 WT
®
ABIMIG
240/401/
501D WT
Gas nozzle
1
Contact tip
2
Equipping the torch ABIMIG
Fig. 1
In case of emergency, immediately interrupt the power, compressed-air and
shielding gas supplies. Further measures can be found in the "Power supply"
operating instructions or in the documentation of further peripheral devices.
DANGER
Risk of injury due to unexpected start-up.
For the entire duration of maintenance, servicing, dismounting and repair
work, the following instructions must be adhered to:
• Switch off the power supply and cut off the gas supply.
• Close off the compressed-air supply and pull the main plug.
CAUTION
Risk of injury
Through-hole or puncture caused by electrode tip.
• Do not reach into the danger zone and wear protective gloves.
Equip the torch neck according to the following figure:
1
Gas diffuser
3
Tip adaptor
4
®
401/501 WT/240/401/501 D WT
1 Screw the replaceable tip adaptor to the torch neck
®
(refers to ABIMIG
The following steps refer to all torch types.
2 Screw gas diffuser onto tip adapter.
2
3
4
5
240D/401D/501D WT).
4 Putting into operation
5
Torch neck