7. Life phases

7.8.2 Putting a number of lifting columns into operation

Test the safe state of the lifting columns.
Insert the connector of the lifting columns supply line in the connecting socket of the
controller marked for the drive.
Insert the connector of the hand switch connector in the connecting socket of the controller
marked for the connector assignment.
Carry out an initializing run (see control assembly instructions).
Note when raising and lowering the lifting column that this operates the limit switches and at
the same time switches the lifting movement off in the top and bottom end positions.

7.9 Maintenance of the lifting column

Basically, the lifting column does not require maintenance, but it is not exempt from wear. This
means that in the case of excessive wear, or in the case of non-replacement of worn product
parts, the safety of the product could be compromised.
Work with the lifting column may only take place in accordance with these instructions.
The device may only be opened by authorized specialist personnel. If there is a fault with the
lifting column, we recommend that you contact the manufacturer or send this lifting column for
repair.
When working on the electrics or the electrical elements, they must be first disconnected from
the supply to prevent any risk of injury.
Unauthorized conversions of or changes to the lifting column are not permitted for safety
reasons. Safety-relevant devices must be inspected for proper function and completeness at
regular intervals.