Service Mode - Bang & Olufsen BeoVision 1 Mode D'emploi

Masquer les pouces Voir aussi pour BeoVision 1:
Table des Matières

Publicité

5.6
Service Mode, English

SERVICE MODE

The Service Mode consists of two parts: Service menu and ignore mode. On page
5.1 see an overview of the Service Mode menus, and operation in Service Mode.
SERVICE MENU
The STAND line is only shown if the TV is fi tted with motorized stand. The function
is described in the section on adjustments.
MONITOR SERVICE MENU
The PICTURE ADJUSTMENTS and GEOMETRY ADJUSTMENTS lines are described in
the section on adjustments.
MONITOR INFORMATION
- Software version numbers
The "STB SW 1.0" line is only shown if the M2 Processor, 1IC200 SDA6000, is
fi tted with set top box controller software.
The "STB TABLE 1.0" line shows the version of conversion of set top box remote
control codes into Beo4 codes.
- Type, item and serial numbers
- Theft protection status. Shows if the Master code is correctly entered (STORED/
NOT STORED)
- Option programming
- Latest fi ve TV errors
- Latest ML error
- Latest AVL error from the V.TAPE and AV sockets
OPTION SETTING
Option 0 = The IR receiver of the TV is disconnected.
Option 1 = The TV and the Audio system (BeoLink system) are placed in the same
room.
Option 2 = The TV and the Audio system (BeoLink system) are placed in different
rooms.
Option 5 = The TV and the Audio system (BeoLink system) are placed in the same
link room.
Option 6 = The TV is the only product in the link room.
ERROR:TV
The TV is able to detect certain types of error and display them on the screen.
The fi ve latest TV errors are shown as error codes and displayed with the month/
date (four digits) as provided by the system clock. The most recent error is
displayed at the top. As the TV has no hardware clock the displayed month/date
will not be correct, but can be used to see if more errors have occurred at the
same date.
The following TV error types can be displayed:
. . . .
No error registered
DF
Data failure
POR1
Power on reset failure 1
POR2
Power on reset failure 2
PDD
Power down detected failure
XX-YZ
(XX = IIC address
Y = IIC bus 1 or bus 2
Z = any IIC bus segment A/B/C/D)

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

863086328633863586368638

Table des Matières