6.3
Cleaning the pump
• Unplug the filter from the mains and open it as described under point 6.2.
• Unscrew the two cross-recessed screws and carefully remove the cover of the pump. Carefully clean the impeller, axle and
pump housing. The impeller (art. no. 5605) and the axle (art. no. 5609) are available as spare parts.
• Reassemble the pump via the reverse procedure. Important: Do not overtighten the screws
7 Technical data
Mains voltage/mains frequency: 230 V / 50 Hz
Wattage:
Max. pump delivery rate:
Max. lifting height:
Mains lead:
IP 44
9 Guarantee conditions
Guarantee period: 24 months (excluding parts subject to wear)
When submitting guarantee claims, please send the equipment to Dennerle's Customer Service department together with the receipt providing proof of pur-
chase.
The guarantee covers manufacturing and material defects. Defective parts will be replaced or repaired free of charge during the guarantee period provided that
the product has been used in the correct manner and for the intended purpose.
During the guarantee period, the device may only be opened by Dennerle's Customer Service personnel, otherwise the guarantee coverage will lapse.
No claims shall be assertible beyond the value of the device, e.g. for damage to fish or plants.
We reserve the right to carry out technical modifications.
Sales / distribution: Dennerle GmbH, D-66957 Vinningen, Germany
Customer Service: DENNERLE GmbH, Industriestraße 4, D-66981 Münchweiler, Germany
www.dennerle.com
10
11,5 W
360 l/Std.
60 cm
1,40 m
8 Spare parts and accessories
5605
Impeller
5609
Axle for impeller
5606
Washer for upper cover
5603
Bio FilterTubes, 500 ml
5604
Bio foam
5607
Fine filter pad with active carbon
5608
Turbo-Skimmer