1-08415_0115_GA Mehrweg_Space_Layout 1 07.01.2015 11:27 Seite 15
6 What if ... – Troubleshooting
Fault
Cause
A faint hissing sound
Pressure reducer is
is to be heard at the
skew or has not been
screwed connection
screwed in tight
between pressure re-
enough.
ducer and CO
cylinder.
2
Washer dirty or faulty.
Adapter is loose
No more bubbles at
the CO
diffusor.
2
Solenoid valve closed
CO
cylinder empty
2
Setting knob closed
Hose connection
leaking
Needle valve blocked
Flipper is still in the
CO
bubbles stuck in
2
running-in phase.
the Flipper.
Obstacles on the chan-
nels (snails, algae).
Flipper not installed in
Gas escaping from
vertical position.
the side of the
collector.
Waste air vent (slit)
soiled.
7 Technical data
Maximum permissible cylinder pressure (operating pressure): 160
bar
Connection for hose 4/6 mm
Dynamic Valve Control (DVC) for precision control
Factory-calibrated precision needle valve with stainless steel needle,
adjustable via ultra-fine thread
Self-closing pressure-relief valve
Transformer: 230 V~ / 50 Hz
Integrated solenoid valve 9 V
Power consumption: 3 W
Mains lead length: 1,40 m
16
8 Spare parts and useful accessories
(available from specialist retailers)
Remedy
3013
3047
Unscrew pressure re-
3048
ducer and screw back
1484
in place without can-
3060
ting.
3053
3040
3093
Clean sealing surfa-
3056
ces, or replace
3035
washer if necessary
2997
Screw in the adapter
10
firmly
Open solenoid valve
Guarantee period: 4 years from date of purchase.
Replace the CO
cy-
When submitting guarantee claims, please send the equipment to Den-
2
linder
nerle's Customer Service department together with the receipt
Open setting knob
providing proof of purchase.
The guarantee covers manufacturing and material defects. Defective
Check hose
parts will be replaced or repaired free of charge during the guaran-
connection, replace
tee period, provided that the equipment has been used only in the
if necessary
correct manner and for the intended purpose.
Clean and recalibrate
During the guarantee period, the device may only be opened by Den-
the needle valve.
nerle's Customer Service personnel, otherwise the guarantee cove-
Await end of
rage will lapse.
running-in phase.
No claims shall be assertible beyond the value of the device, e.g. for
Clean.
damage to fish or plants.
Fit Flipper in an up-
We reserve the right to carry out technical modifications.
right position.
Clean.
Sales / distribution: DENNERLE GmbH, D-66957 Vinningen,
Customer Service:
Disposable CO
cylinder 500 g
2
Reusable CO
cylinder, 500 g
2
Reusable CO
cylinder, 2000 g
2
Leak detector spray
Special Softflex CO
hose, 2 m
2
Special CO
check valve
2
CO
long-term test Correct
2
pH controller Evolution Deluxe
2 washers for adapter on reusable cylinders
2 washers for Space pressure reducer
Adapter for disposal CO
cylinders
2
Guarantee conditions
Germany
DENNERLE GmbH, Industriestraße 4,
D-66981 Münchweiler, Germany
www.dennerle.com