Example: Activate / deactivate levels
Display level L3 -
1.
Activate programming mode using the key combination < H > and then < V >.
When programming mode is activated,
+
the "M-" symbol will flash.
2.
Press the < H > key several times briefly until the segment
block for setting the respective level flashes.
3.
Press the < V > key briefly in order to deactivate or
activate the respective level.
4.
Press the < H > briefly to jump to the number of the next
available level.
5. Repeat steps 3 and 4 until the required levels have been activated / deactivated.
If display level 3 is deactivated, the device can then only be parameterised using the
parameterisation software.
6.
Confirm acceptance of the password using the key combination < H > and then < V >.
+ Result of this example:
Levels 2, 3 and 5 are shown,
4x spaces = Levels 4, 6, 7 and 8 are not available
= Level 9 is hidden
Example: Changing the dimensioning unit
Display level L3 - display "possible + active levels"
1.
Activate programming mode using the key combination < H >
and then < V >. When programming mode is
+
activated, the "M-" symbol will flash.
2.
Press the < H > key briefly several times until the symbol for
the dimensioning unit with the decimal frame flashes.
3.
Press the < V > key briefly to change the dimensioning
unit.
4.
Confirm acceptance of the password using the key combination < H > and then < V >.
+
All other device parameters can be set in accordance with the pattern in the examples
shown.
EN
62
display "possible + active levels"
MU2H-0501ge23 R1020
(kWh ↔ MWh or MJ ↔ GJ)
V1.00 / 3.5.2018