Programmable Parameters; Example: Programming The Due Date - Honeywell Home Resideo EW701 Instructions De Service Et De Montage

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 95

Programmable parameters

Next due date
Activate / deactivate levels
Change the dimensioning unit
(kWh ↔ MWh or MJ ↔ GJ)
Switch the checksum display on/off
(postcard readout)

Example: Programming the due date

Display level L3 -
1.
Activate programming mode using the key combination < H > and then < V >.
+ When programming mode has been activated, the segment
block for setting the value "year" flashes first.
2.
Press the < V > key several times briefly until the value
"year" for the new due date has been reached.
3.
Only press the < V > key if you want to skip the first due date.
Press the < H > key in order to jump to the segment block for
setting the value "month".
4.
Press the < V > key several times briefly until the value
"month" for the new due date has been reached.
5.
Confirm acceptance of the password using the key combina-
tion < H > and then < V >.
+
Only the last day of a month can be chosen as the
due date. (February, always on the 28th.)
V1.00 / 3.5.2018
display "due date"
MU2H-0501ge23 R1020
L3
L3
L3
L3
61
EN

Publicité

Table des Matières
loading

Table des Matières