CHIMNEY
DO NOT CONNECT THIS UNIT TO A CHIMNEY FLUE SERVING ANOTHER APPLIANCE. DO NOT
CONNECT TO ANY AIR DISTRIBUTION DUCT OR SYSTEM.
This room heater must be connected to a 6" factory built UL 103 HT chimney (ULC S629, in
Canada) or a code-approved masonry chimney with a fl ue liner.
FACTORY BUILT CHIMNEY
When a metal prefabricated chimney is used, the manufacturer's installation instructions must
be followed. You must also purchase (from the same manufacturer) and install the ceiling sup-
port package or wall pass-through and "T" section package, fi restops (where needed), insula-
tion shield, roof fl ashing, chimney cap, etc. Maintain proper clearance to the structure as rec-
ommended by the manufacturer. The chimney must be the required height above the roof or
other obstructions for safety and proper draft operation. See page 8 for chimney termination
requirements.
Listed Cap
Listed Chimney
Storm Collar
Flashing
Attic Insulation Shield
Maintain 2" Clearance
Combustible Ceiling Joists
Specifi ed Clearance
Listed Chimney
Chimney Connector
Chimney Connector
Ceiling Support
*
*
Refer to Clearances to Combustibles
5