INSTALLATION CLEARANCES TO COMBUSTIBLES
It is extremely important that you respect required installation distances and that you respect
local installation regulations. This is for your safety! The manufacturer is not responsible for the
product, if it is not installed following these recommendations. These clearances may only be
reduced by means approved by the regulatory authority.
A combustible surface is anything that can burn (i.e. sheet rock, wall paper, wood, fabrics etc.)
These surfaces are not limited to those that are visible and also include materials that are behind
non-combustible materials. If you are not sure of the combustible nature of a material, consult
your local fi re offi cials.
Minimum clearance to combustibles:
Backwall
E
D
A
Clearance requirements:
A. Sidewall
B. Backwall
C. Cornerwall
D. Sidewall to connector
E. Backwall to connector
F. Cornerwall to connector
3
B
45 º
Standard residential installation (singlewall connector)
Mini XV1
9.0" (229mm)
7.5" (191mm)
7.5" (191mm)
19.0" (483mm)
12.5" (318mm)
19.0" (483mm)
Adjacent wall
F
C
Maxi XV2
17.0" (431mm)
9.0" (229mm)
11.0" (279mm)
30.0" (761mm)
12.0" (305mm)
14.0" (355mm)