Copie De L'étiquette De Sécurité - Regency Classic C34-NG10 Gaz Naturel Guide D'installation Et D'utilisation

Autoportante poêle au gaz
Table des Matières

Publicité

6 |
l'étiquette de sécurité
Ceci est une copie de l'étiquette d'homologa-
tion qui accompagne chaque Poêle au Gaz
CLASSIC. Nous avons imprimé une copie de
son contenu pour révision. L'étiquette d'ho-
mologation est située à l'intérieur de la porte
du piédestal.
COPIE DE L'ÉTIQUETTE DE SÉCURITÉ
Listed: VENTED GAS FIREPLACE HEATER / FOYER AU GAZ À ÉVACUATION
Certified for/Certifi e pour: CANADA and U.S.A.
é
Tested to: CAN/CGA-2.17-M91(R2009)
Conforms to:
ANSI Z21.88-2014
Certified to:
CSA 2.33-2014
4001172
MAY BE INSTALLED IN MANUFACTURED (MOBILE) HOMES AFTER FIRST SALE
NATURAL GAS STOVE:
Model C34-NG10
L
Minimum supply pressure
Manifold pressure high
Manifold pressure low
Orifice size
Minimum input
Maximum input
Altitude
PROPANE GAS STOVE:
Model C34-LP10
L
Minimum supply pressure
Manifold pressure high
Manifold pressure low
Orifice size
Minimum input
Maximum input
Altitude
This appliance must be installed in accordance with local codes, if any; if none, follow the National Fuel Gas Code, ANSI Z223.1, or Natural Gas and Propane Installation
Code, CSA B149.1.
This appliance must be installed in accordance with the Standard CAN/CSA Z240 MH, Mobile Housing, in Canada, or with the Manufactured Home Construction and Safety
Standard, Title 24 CFR, Part 3280, in the United States, or when such a standard is not applicable, ANSI/NCSBCS A225.1/NFPA 501A, Manufactured Home Installations
Standard or ANSI A119.2 ou NFPA 501C Standard for Recreational Vehicles
This appliance is only for use with the type of gas indicated on the rating plate and may be installed in an aftermarket, permanently located, manufactured (mobile) home where
not prohibited by local codes. See owner's manual for details. Optional Fan Kit (Part # 493-917)
Installer l'appareil selon les codes ou règlements locaux, ou, en l'absence de tels règlements, selon les codes d'installation ANSI Z223.1, National Fuel Gas Code ou CSA-B149.1
en vigueur.
Installer l'appareil selon la norme CAN/CSA-Z240, Série MM, Maison mobiles ou CAN/CSA-Z240 VC, Véhicules de camping, ou la norme 24 CFR Part 3280, Manufactured
Home Construction and Safety Standard. Si ces normes ne sont pas pertinentes, utilisez la norme ANSI/NCSBCS A225.1/NFPA 501A, Manufactured Home Installations
Standard, ou ANSI A119.2 ou NFPA 501C Standard for Recreational Vehicles.
Cet appareil doit être utilize uniquement avec le type de gaz indiqué sur la plaque signalétique. Cet appareil peut être installé dans une maison préfabriquée ou mobile (É.-U.
seulement) installée à demeure si les règlements locaux le permettent. Voir la notice de l'utilisateur pour plus de renseignements. Cet appareil ne peut pas être utilisé avec
d'autres gaz sauf si une trousse de conversion certifiée est fournie.
This vented gas fireplace heater is not for use with air filters.
For use with glass doors certified with the appliance only
For Use Only with Barrier (Part # 493-005) Follow installation instructions.
VENTED GAS FIREPLACE HEATER - NOT FOR USE WITH SOLID FUELS.
FOYER AU GAZ À ÉVACUATION -
Part #: 919-489
For the State of Massachusetts, installation
Colour: Black on Grey except selected text is in red as per this print.
and repair must be done by a plumber or
Size:
Printed at 100%
gasfitter licensed in the Commonwealth of
Material: 2 ml silver matt polyester (DPM SMS)
Massachusetts.
Dec. 09/14: Created decal
*Printer: Continue number sequence from 918-490 - do not restart at 0
For the State of Massachusetts, flexible
connectors shall not exceed 36 inches in
length.
For the State of Massachusetts, the appli-
ances individual manual shut-off must be a
t-handle type valve.
The State of Massachusetts requires the
installation of a carbon monoxide alarm in
accordance with NFPA 720 and a CO alarm
with battery back up in the same room where
the gas appliance is installed.
6
|
Regency C34-10 Poêle au Gaz à Évacuation Directe CLASSIC™
NOTE: Les appareils Regency sont constam-
ment améliorés. Vérifiez l'étiquette d'homolo-
gation sur votre appareil et si elle diffère des
informations apparaissant sur la copie illustrée
ici, respectez les exigences de l'étiquette d'ho-
mologation sur l'appareil.
P
APPAREIL FONCTIONNANT AU GAZ NATURAL
L
CONCU POUR ETRE POELE:
5"
WC (1.25kpa)
Pression d'allimentation minimum
3.8" WC (0.94kpa)
Pression à la tubulure d' chappement lev e
1.1" WC (0.27kpa)
Pression à la tubulure d' chappement basse
#36
(2.71mm)
Grandeur de l'injecteur
16000 BTUH (4.69 kw/h)
D bit Calorifique minimum selon
é
32000 BTUH (9.38 kw/h)
D bit Calorifique maximum selon
é
0-4500 ft/pi (0-1372m)
l'altitude
P
APPAREIL FONCTIONNANT AU PROPANE
L
CONCU POUR ETRE POELE:
12" WC (2.98 kpa)
Pression d'allimentation minimum
11" WC (2.73 kpa)
Pression à la tubulure d' chappement lev e
2.9" WC (0.72 kpa)
Pression à la tubulure d' chappement basse
#52
(1.61mm)
Grandeur de l'injecteur
16000 BTUH (4.69 kw/h)
D bit Calorifique minimum selon
é
32000 BTUH (9.38 kw/h)
D bit Calorifique maximum selon
é
0-4500 ft/pi (0-1372m)
l'altitude
Ne pas utiliser de filtre à air avec ce foyer au gaz à évacuation.
Pour utilisation uniquement avec les portes en verre certifiées avec l'appareil
Utiliser uniquement avec l'écran ( n ° 493-005) Suivre les instructions d'installation.
NE PAS UTILISER AVEC DU COMBUSTIBLE SOLIDE.
DUPLICATE SERIAL NO.
DO NOT REMOVE THIS LABEL / NE PAS ENLEVER CETTE ÉTIQUETTE
Modéle C34-NG10
é
é
é
é
Modéle C34-LP10
é
é
é
é
297
Serial No./ No de serie
297
Minimum Clearances to Combustibles /
Degagement Minimum
De Materiaux Combustibles
Back wall
B
A
A
Back wall
A 10"/250mm
B 6"/150mm
E 1.5"/38mm
E
Minimum ceiling height from
top of unit:36"/914mm
Minimum plafond hauteur en
haut de l'appareil: 36"/914mm
Minimum clearance to vent 1.25"/32mm
DOOR SEAL:
Please check that the door is properly sealed.
ELECTRICAL SUPPLY/ALIMENTATION ELECTRIQUE:
115V_60HZ less than/moins de 2 AMP
FPI Fireplace Products International Ltd.
Delta, BC, Canada
Made in Canada/
919-489
Fabrique au Canada

Publicité