Primary filter replacement

Figure 14
1.
Vacuuming unit
2.
Locking lever
3.
Filter cage
4.
Primary filter
5.
Filter shaker housing
WARNING!
Take care not to raise dust when this operation is
carried out. Wear a mask and other protective clothing
plus protective gloves suited to the hazardous nature
of the dust collected, refer to the laws in force.
Before proceeding with these operations, turn the vacuum
cleaner off and disconnect the plug from the power socket.
Use lever (2) to release vacuum unit (1) then pull it up
and out of the vacuum cleaner.
Remove the filter cage from the vacuum cleaner.
Remove the old filter by removing the plastic ties..
Fit the new filter and secure it in the cage with new
plastic ties.
Dispose of the old filter according to the laws in force.
Replacing a primary filter with automatic filter
shaker
WARNING!
Reassemble with care to avoid trapping your hands
between the vacuum unit and the container.
After replacing the filter in the cage (3), install it in the
container again.
Reassemble vacuum unit (1) making sure filter cage (3)
fits into shaped housing (5) of the filter shaker.
Turn the power switch on and the vacuum unit will self-
centre automatically.
Use locking lever (2) to lock the vacuum unit in place.
02/2013
Replacing a primary filter with manual filter shaker
1.
Manual filter shaker knob
2.
Vacuuming unit
3.
Locking lever
4.
Filter cage
5.
Filter shaker housing
Reassemble with care to avoid trapping your hands
between the vacuum unit and the container.
After having replaced and fitted the filter in the cage,
insert filter shaker cage (4) in the shaped seat (5) of the
filter shaker.
Position the manual filter shaker knob (1) in the middle.
Reassemble vacuum unit (2) complete with cage and
filter, in the vacuum container.
Check the filter shaker works properly and if necessary
adjust the position of the filter cage by turning the
vacuum unit.
Use locking lever (3) to lock the vacuum unit in place.