Troubleshooting - AquaScape ULTRAKLEAN 2000 Mode D'emploi

Masquer les pouces Voir aussi pour ULTRAKLEAN 2000:
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

5. grip the base of the uV bulb and pull it free from the four-
pronged socket.
6. replace uV bulb in reverse to the order it was removed.
NOTe: Do not touch UV bulb with bare hands
as the oil from skin will reduce the bulbs
performance and lifespan.
use a clean lint free cloth to wipe off any dirt or smudges
on the bulb prior to reinstalling the control panel into the lid
of the filter. also, make sure there is no moisture inside the
quartz sleeve or on the bulb prior to reassembly.
• Winter Storage – the ultraKlean
shutdown and stored indoors or in a garage if your pond
is subject to freezing. if you've buried the canister body we
recommend removing it from the ground to avoid possible
damage. when disconnecting the tubing from the filter, the
threaded fittings should be removed without the need for
any tools (be careful not to lose the flat rubber washers).
www.aquascapeinc.com |
pond filter should be
CAN 1-866-766-3426 |

trOUblEShOOting

rEdUCEd watEr FlOw
• all pressure filters even when new and clean will reduce
water flow from pump by approximately 50%. it is
recommended to use the largest diameter tubing possible
(up to 1½ inch diameter) in order to achieve maximum
water flow rates.
• the ultraKlean
bioballs
a backwash cleaning.
• pump or plumbing may be clogged. it may be necessary
to clean the pump cage screens and impeller.
UV light iS nOt On
• cycle timer is not set to the 6 hr/12 hr or 24 hr setting
• power to the ultraKlean
to be sure it's plugged in and the ground fault breaker is
not activated.
• uV internal bulb connection may be loose. remove the
ultraKlean
pond filter lid and unscrew the threaded collar
holding the quartz sleeve in place over the bulb. check to
be sure the uV bulb itself seats securely down where the
bulb plugs a four-pronged base into a receptacle inside
the lid. also when replacing the quartz sleeve be sure
the collar is snug when tightened as tightening the collar
activates the safety switch for the uV light.
• uV bulb could be beyond its life expectancy.
replace uV light.
US 1-866-877-6637
could be clogged and require
pond filter has been lost. check
11