TLV TRAP STATION V1 Serie Installation page 2

Masquer les pouces Voir aussi pour TRAP STATION V1 Serie:
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

Specifications
Model
Name
Inlet/Outlet Valve
Body Material
Size
Max. Allowable Press. PMA* /
Max. Allowable Temp. TMA*
Max. Operating Press. PMO** /
Max. Operating Temp. TMO**
Applicable Fluid
Connectable TLV products
(Trap Unit Models)
NOTE: Some models may not be
available in all regions.
* Maximum Allowable Pressure (PMA) and Maximum Allowable Temperature (TMA) are
PRESSURE SHELL DESIGN CONDITIONS for trap station only, NOT OPERATING CONDITIONS.
** For trap station only; further restricted by mounted trap unit.
Model
Appearance
Flow Diagram
Flow Direction
Blowdown Valve
Test Valve
Model
Appearance
Flow Diagram
Flow Direction
Blowdown Valve
Test Valve
V1-RL / V1-RB / V1-LB
Only at the inlet side
4.6 MPaG (650 psig) / 425 °C (800 ˚F)
4.6 MPaG (650 psig) / 425 °C (800 ˚F)
Free Float Steam Traps
S3, S5, S5H, S3-K, S5-K
Other trap units may be applicable. Contact TLV for QuickTrap models not listed.
V1-RL
or
or
Right or Left
̶
̶
V2-RL
or
or
Right or Left
̶
̶
V2-RL / V2-RB / V2-LB
TRAP STATION
SUS304
/
/
15, 20 mm (
1
,
3
in)
2
4
Steam, Condensate
Disc Type Steam Traps
P46UC
P32
V1-RB
Right
̶
V2-RB
Right
Inlet/outlet side
Thermostatic Steam Traps
L5, L21, L32, L5-C, L21-C, L32-C
X1
(1 MPa = 10.197 kg/cm
V1-LB
Left
̶
V2-LB
Left
2
)

Publicité

Table des Matières
loading

Table des Matières