Fault - Angelo Po 0G0FR3E Manuel D'utilisation Et D'installation

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

CLEANING WELL, BASKETS AND BASKET SUPPORT STRUCTURE
To carry out this operation,
proceed as follows.
1 - Switch the appliance off
and leave it to cool (see
page 7).
2 - Turn off the circuit-
breaker to disconnect it
from
the
mains.
3 - Drain and filter the oil
(see page 8).
4 - Remove and clean the
baskets and the basket
support structure (A).
5 - Turn the heating elements into the vertical posi-
tion.
6 - Apply a food-grade detergent to the inside of the
well.
7 - Rinse the well with drinking water and
drain.
The appliance has been tested before being put into
IT
service. The information provided below is intended
to assist in the identification and correction of any
GB
anomalies and malfunctions which might occur dur-
ing use. The user can solve some of these prob-
DE

Fault

FR
The heating elements do not
ES
come on.
English
A
electrical
TROUBLESHOOTING
Electrical connection not made
Safety thermostat tripped.
8 - Apply a specific product or a water and vinegar
solution to the well to remove the detergent res-
idues.
9 - Rinse, empty and dry the well.
10-After use, clean the accessories with a suitable
grease-remover product. If possible, wash in
the dishwasher.
FAULT
lems himself, but for others specific technical
knowledge or skill is required, and so they must only
be carried out by qualified staff with recognised ex-
perience acquired in the specific sector of operation.
Cause
correctly.
Switch faulty.
- 10 -
IDM-39604002100.tif
Remedy
Check the connection of the
electrical wires.
Carry out the appliance reset
(see page 14).
Replace the switch.
6

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

1g0fr4e

Table des Matières