ABIMIG
1
4
1
Control lead
2
Coolant supply hose
Fig. 6
Connecting the coolant
2
3
Coolant recirculator
NOTICE
• Ensure that the coolant supply and return hoses have been correctly
installed. Coolant supply = blue, coolant return = red.
• Do not use deionised or demineralised water as coolant or for leak and
flow tests.
This may shorten your welding torch's service life.
• For liquid-cooled welding torches, we recommend using
ABICOR BINZEL BTC coolant.
Please consult the applicable safety data sheet.
• The cooling system must be purged of any air each time the device is
commissioned and after every cable assembly change: disconnect the
coolant return hose from the coolant recirculator and hold it over a
collection receptacle. Close the opening on the coolant return hose. Then
re-open it by abruptly releasing it. Repeat until the coolant flows into the
collection receptacle continuously and without air bubbles.
5 Putting into operation
3
4
Coolant return hose