Enabling Act - Zephyr Luce ZLU-E30CS Guide D'utilisation, D'entretien Et D'installation

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

ZEPHYRONLINE.COM

Enabling ACT™

To enable ACT™:
1. Before hood installation, gain access to PC board by following the steps shown on FIG. I.
2. Change plastic jumper positioning as shown in FIG. J to set the desired maximum blower CFM.
3. Re-install PC board and continue with hood installation.
4. Remove the appropriate foil CFM sticker included with the hood literature and place inside the
hood body below the wiring diagram or in another clearly visible location.
To verify if your installer enabled ACT™:
1. With hood off, hold the power button for three seconds. If 5 LEDs illuminate = default max. If 4
LEDs illuminate = max. 390 CFM, and if 3 LEDS illuminate = max. 290 CFM.
2. When ACT™ is enabled, the number of blower speeds will be reduced. 390 CFM = max. 4 speeds
and 290 CFM = max. 3 speeds.
3. There should also be a foil label located inside the hood body near the wiring diagram that
indicates the blower CFM.
Models: ZLU
- Locate PC board box on top of blower housing.
- Remove 2 to 4 screws attaching PC board cover.
FIG. I
Luce Use, Care, and Installation Guide
ACT™ Conversion
7
8
5
6
3
4
1
2
J u m p e r 3 - 4
Max. Blower CFM
PC Board
FIG. J
Jumper Pins
7
8
5
6
3
4
1
2
J u m p e r 5 - 6 or 7-8
DEFAULT POSITION
Default Max. Blower CFM
7
8
7
5
6
5
3
4
3
1
2
1
J u m p e r 1 - 2
Max. Blower CFM
390
Plastic
Jumper
8
6
4
2
290
23

Publicité

Chapitres

Table des Matières
loading

Ce manuel est également adapté pour:

Luce zlu-m90cs

Table des Matières