Installation site selection - Indoor unit
AVOID
• Direct sunlight.
• Nearby heat sources that may affect unit performance.
• Areas where leakage of flammable gas may be expected.
• Locations where large amounts of oil mist may occur (such as in
kitchen or near factory equipment) because oil contamination can
cause operation problems and may deform plastic surfaces and parts
of the unit.
• Unsteady locations that will cause noise or possible water leakage.
EG
• Locations where the remote control unit will be splashed with water
or affected by dampness or humidity.
• To make holes in areas where electrical wiring or conduits are located.
• To place appliances under tension (household appliances, computers),
because in case of emergency operation the unit could drip condensate
water.
ADDITIONAL MATERIAL REQUIRED FOR INSTALLATION (NOT SUPPLIED)
G
Deoxidized annealed copper tube for refrigerant tubing connecting the units of the system; it has to be insulated with foamed polyethylene
(min. thickness 8mm).
MODEL
CA/CAV92
CA/CAV122-182
G
PVC pipe for condensate drain pipe (ø int.18mm) in lenght suitable to let the condensate flow into the outside drainage.
G
Anti-freeze oil for flare connections (about 30g.).
G
Electric wire: use insulated copper wires of size and length as shown in the table "ELECTRICAL DATA" and at paragraph "SYSTEM WIRING
DIAGRAMS".

ELECTRICAL DATA

MODEL
Cross section area (mm
2
)
GR/GRV92
GR/GRV122
GR/GRV182
* 3-phase version
TUBING LENGTH AND ELEVATION DIFFERENCE LIMITS
MODEL
CA/CAV92
CA/CAV122-182
* If total tubing length becomes 7,5 to 15m, 7,5 to 20m (max.), charge additional refrigerant a) 15g/m, b) 25g/m.
No additional charge of compressor oil is necessary.
NARROW TUBE
OUTER DIAMETER
6,35 mm
6,35 mm
LENGTH, SIZE WIRES AND DELAYED FUSE
Power supply wiring length
("A-B") m
2,5
15
10
15
85*
MAX. ALLOWABLE
TUBING LENGTH AT
SHIPMENT
(m)
7,5
7,5
DO
• Select an appropriate position from which every corner of the room
can be uniformily cooled.
• Select a sufficiently strong ceiling to support the weight of the unit.
• Select a location where tubing and drain hose have the shortest run
to the outside.
• Allow access for operation and maintenance as well as unrestricted
air flow around the unit.
Installation site selection - Outdoor unit
AVOID
• Heat sources, exhaust fans.
• Direct sunlight.
• Damp, humid or uneven locations.
• To make holes in areas where electrical wiring or conduits are located.
DO
• Choose places as cool as possible and well ventilated.
• use lug bolts or equal to bolt down the unit, reducing vibration and
noise.
MIN. THICKNESS
OUTER DIAMETER
0,8 mm
0,8 mm
Power line length
("C") m
2,5
15 m
20 m
20 m
LIMIT OF TUBING
LIMIT OF ELEVATION
LENGTH
(m)
15
20
4
LARGE TUBE
MIN. THICKNESS
9,52 mm
12,7 mm
Control line length
("D") m
1
20 m
20 m
20 m
REQUIRED AMOUNT OF
DIFFERENCE
ADDITIOONAL
H
REFRIGERANT
(m)
7
7
0,8 mm
0,8 mm
Delayed fuse
10A
10A
20A
10A
(g / m)*
a) 15
b) 25
(go on page 5)