Publicité

Liens rapides

See Warranty on page 6 for important information about commercial use of this product.
Operating Instructions
Please read and save these instructions. Read carefully before attempting to assemble, install, operate or maintain the product described.
Protect yourself and others by observing all safety information. Failure to comply with instructions could result in personal injury and/or
property damage! Retain instructions for future reference.
Portable Air Compressors
Description
Portable oilless air compressors are for
home and workshop use. All models
are equipped with regulators, needle
and ball bearings and 1725 or 3450
RPM, 60 Hz motors with automatic
overload protection. Cleaning or
replacement of the inlet filter on all
models and draining moisture from the
air receivers are required maintenance.
Safety Guidelines
This manual contains information that is
very important to know and understand.
This information is provided for SAFETY
and to PREVENT EQUIPMENT PROBLEMS.
To help recognize this information,
observe the following symbols.
Danger indicates
DANGER
!
an imminently
hazardous situation which, if not
avoided, will result in death or serious
injury.
Warning indicates
WARNING
!
a potentially
hazardous situation which, if not
avoided, could result in death or
serious injury.
Caution indicates a
CAUTION
!
potentially
hazardous situation which, if not
avoided, MAY result in minor or
moderate injury.
Notice indicates
NOTICE
important
information, that if not followed, may
cause damage to equipment.
Unpacking
When unpacking unit, inspect carefully
for any damage that may have occurred
during transit. Make sure any loose
fittings, bolts, etc., are tightened before
putting unit into service.
REMINDER: Keep your dated proof of purchase for warranty purposes! Attach it to this manual or file it for safekeeping.
© 2002 Campbell Hausfeld/Scott Fetzer
EX8000, WL5000 Series Contractor Models
General Safety
Air compressors are utilized in a variety
of air system applications. Because air
compressors and other components
(material pump, spray gun, filters,
lubrications, hoses, etc.) used make up a
high pressure pumping system, the
following safety precautions should be
observed at all times. Only persons well
acquainted with these rules of safe
operation should be allowed to use the
air compressor.
All electrical work
WARNING
!
should be done by a
qualified (licensed or certified)
electrician. On a properly wired circuit,
the black wires supply a voltage
potential even when the unit is off.
1. Read instruction manuals for each
component carefully, before
attempting to assemble,
disassemble or operate your
particular system.
2. Do not exceed pressure rating of
any component in system.
3. Protect material lines and air lines
from damage or puncture. Keep
hose and power cable away from
sharp objects, chemical spills, oil,
solvents, and wet floors.
4. Never point a spray gun at oneself
or any other person. Accidental
discharge may result in serious
injury.
5. Check hoses for weak or worn
condition, before each use, making
certain all connections are secure;
do not use if deficiency is found.
Notify an authorized service facility
for examination or repair.
6. Release all pressures within system
For parts, product & service information
visit www.chpower.com
DANGER
!
Breathable Air Warning
This compressor/pump is not
equipped and should not be used
"as is" to supply breathing
quality air. For any application of
air for human consumption, the
air compressor/pump will need
to be fitted with suitable in-line
safety and alarm equipment. This
additional equipment is
necessary to properly filter and
purify the air to meet minimal
specifications for Grade D
breathing as described in
Compressed Gas Association
Commodity Specification G 7.1 -
1966, OSHA 29 CFR 1910. 134,
and/or Canadian Standards
Associations (CSA).
DISCLAIMER OF WARRANTIES
In the event the compressor is
used for the purpose of
breathing air application and
proper in-line safety and alarm
equipment is not simultaneously
used, existing warranties shall be
voided, and Campbell Hausfeld
disclaims any liability
whatsoever for any loss,
personal injury or damage.
slowly; dust and debris may be
harmful.
Disconnect power
WARNING
!
and depressurize
system before servicing air compressor!
(Turn pressure regulator knob fully
clockwise after shutting off
compressor.)
7. Follow all local electrical and safety
IN602302AV 12/02

Publicité

Table des Matières
loading

Sommaire des Matières pour Campbell Hausfeld EX8000 Serie

  • Page 1 7. Follow all local electrical and safety REMINDER: Keep your dated proof of purchase for warranty purposes! Attach it to this manual or file it for safekeeping. © 2002 Campbell Hausfeld/Scott Fetzer For parts, product & service information IN602302AV 12/02...
  • Page 2 Portable Air Compressors General Safety 21. Use a respirator when spraying. 3. Compressor should be located where (Cont.) it can be directly plugged into an 22. NEVER reset safety valve or pressure codes, as well as the National Electrical outlet, but if this is not possible, an switch.
  • Page 3: Important

    EX8000, WL5000 Series Contractor Models ✽ Wire and Terminal Guide Installation (Cont.) Wire Color Terminal appropriate grounding plug. Plug Power cord White Line must be plugged into an outlet that Motor cord White Load is properly installed and grounded Power cord Black Line in accordance with all local codes...
  • Page 4 Portable Air Compressors Operation Safety valve must If thermal overload protector shuts motor (Cont.) WARNING be replaced if it OFF frequently look for the following REGULATOR KNOB cannot be actuated or it leaks air after ring causes. is released. 1. This knob controls air pressure to an air 1.
  • Page 5: Troubleshooting Chart

    EX8000, WL5000 Series Contractor Models Troubleshooting Chart Symptom Possible Cause(s) Corrective Action Compressor will not run 1. Loss of power or overheating 1. Check for proper use of extension cord (see EXTENSION CORDS, page 3) 2. No electrical power 2. Plugged in? Check fuse/breaker or motor overload 3.
  • Page 6 8. RESPONSIBILITIES OF PURCHASER UNDER THIS WARRANTY: A. Provide dated proof of purchase and maintenance records. B. Portable compressors or components must be delivered or shipped to the nearest Campbell Hausfeld Authorized Service Center. Freight costs, if any, must be borne by the purchaser.
  • Page 7 National Electrical Code (NEC) et \ MÉMENTO: Gardez votre preuve datée d'achat à fin de la garantie! Joignez-la à ce manuel ou classez-la dans un dossier pour plus de sécurité. © 2002 Campbell Hausfeld/Scott Fetzer IN602302AV 12/02 7 Fr...
  • Page 8: Généralités Sur La Sécurité (Suite)

    Compresseurs D’Air Portatifs Généralités Sur La 20. Ne pas pulvériser dans l’endroit d’une Installation flamme ni dans un endroit où une Sécurité (Suite) 1. Vérifier et serrer tous les boulons, étincelle peut précipiter l’allumage. Ne raccords, etc., avant d’utiliser le pas fumer pendant la pulvérisation de le Occupational Safety and Health compresseur.
  • Page 9: Installation (Suite)

    Modèles Pour Entrepreneurs Série EX8000, WL5000 ✽ Guide de Fils et Bornes Installation (Suite) Couleur Borne Chaud INSTRUCTIONS DE MISE À LA TERRE Cordon d’alimentation Blanc Ligne 1. Ce produit doit être mis à la terre. Cordon du moteur Blanc Charge Dans l’évenement d’un court-circuit, Cordon d’alimentation...
  • Page 10: Entretien

    Compresseurs D’Air Portatifs Functionnement 1. Inspecter le compresseur et vérifier ENLEVAGE, INSPECTION ET que le filtre d’air soit propre. REMPLACEMENT DU FILTRE (Suite) 2. Tirer la bague sur la soupape de Pour remplacer un filtre, enlever le sûreté et la permettre de retourner à couvercle du carter de filtre.
  • Page 11: Guide De Dépannage

    Modèles Pour Entrepreneurs Série EX8000, WL5000 Guide De Dépannage Symptôme Cause(s) Possible(s) Mesures Correctives Compresseur ne 1. Perte de puissance ou surchauffage 1. Vérifier l’usage correct des cordons prolongateurs fonctionne pas (voir CORDONS PROLONGATEURS, page 9) 2. Manque de puissance électrique 2.
  • Page 12 2. GARANTIE ACCORDÉE PAR (GARANT): Campbell Hausfeld/Scott Fetzer Company, 100 Production Drive, Harrison, Ohio, 45030, Téléphone: (800) 543-6400 3. BÉNÉFICIAIRE DE CETTE GARANTIE (ACHETEUR): L’acheteur original (sauf en cas de revente) du produit Campbell Hausfeld. 4. PRODUITS COUVERTS PAR CETTE GARANTIE: N’importe quel compresseur d’air Campbell Hausfeld.
  • Page 13 Antes de gravedad. que lo chequeen o reparen. RECORDATORIO: ¡Guarde su comprobante de compra con fecha para fines de la garantía! Adjúntela a este manual o archívela en lugar seguro. IN602302AV 12/02 © 2002 Campbell Hausfeld/Scott Fetzer 13 Sp...
  • Page 14 Compresores de Aire Portátiles tales como solventes secos no Generales de Seguridad Ensamblaje inflamables. (Continuación) PATAS (11,4 L MODELOS 16. Para evitar la combustión espontanea SOLAMENTE) 6. Libere el aire lentamente; de lo tire los trapos que usó para limpiar Introduzca el perno roscado de la pata de contrario éste podría levantar polvo en envases de metal aprobados para...
  • Page 15: Conexion A Tierra

    EX8000, WL5000 Serie de modelos para contratistas ✽ Guía de cables y terminales Instalación Cable Color Terminal Con tensión (Continuación) Cordón eléctrico Blanco Línea Si no Cordón del motor Blanco Tensión PRECAUCION conecta Cordón eléctrico Negro Línea los cables adecuadamente podría haber Cordón del motor Negro Tensión...
  • Page 16 Compresores de Aire Portátiles PERILLA DEL REGULADOR Funcionamiento 1. Esta perilla controla el suministro de (Continuación) aire a las herramientas neumáticas o pistolas pulverizadoras. Figura 5 2. Gírela en el mismo sentido de las Debe HUMEDAD EN EL AIRE agujas del reloj para aumentar la ADVERTENCIA reempla- COMPRIMIDO...
  • Page 17: Protector Termico

    EX8000, WL5000 Serie de modelos para contratistas Mantenimiento Si el protector térmico apaga al ALMACENAMIENTO compresor con mucha frecuencia puede 1. Mientras no lo esté usando debe (Continuación) ser por lo siguiente: almacenar el compresor y las mangueras en un sitio seco y frío. 1.
  • Page 18: Guía De Diagnóstico De Averías

    Compresores de Aire Portátiles Guía de Diagnóstico de Averías Problema Posible(s) Causa(s) Acción a Tomar Compresor no funciona 1. Pérdida de potencia o se 1. Chequee el cordón de extensión adecuado (vea la sobrecalienta sección CORDONES DE EXTENSION, página 15) 2.
  • Page 19 EX8000, WL5000 Serie de modelos para contratistas Guía de Diagnóstico de Averías (Continuación) Problema Posible(s) Causa(s) Acción a Tomar 1. Chequée todas las conecciones con agua enjabonada 1. Conecciones flojas (coneciones, La presión del tanque y apriete las conecciones flojas tuberías, etc.) disminuye cuando el compresor se apaga...
  • Page 20: Garantía Limitada

    Estándard (Standard Duty) - Un año; Productos Resistentes (Serious Duty) -Dos años; Productos Robustos (Extreme Duty) - Tres años; Serie Modelo Maxus - Cinco años. 2. QUIEN OTORGA ESTA GARANTIA (EL GARANTE: Campbell Hausfeld / The Scott Fetzer Company 100 Production Drive, Harrison, Ohio 45030 Teléfono: (800) 543-6400 3.

Ce manuel est également adapté pour:

Wl5000 serie

Table des Matières