Liens rapides

See Warranty on page 8 for important information about commercial use of this product.
Operating Instructions and Parts Manual
Please read and save these instructions. Read carefully before attempting to assemble, install, operate or maintain the
product described. Protect yourself and others by observing all safety information. Failure to comply with instructions could
result in personal injury and/or property damage! Retain instructions for future reference.
BUILT TO LAST
Description
Oilless compressors are designed for
do-it-yourselfers with a variety of home
and automotive jobs. These units
operate without oil. Compressed air
from this unit will contain moisture.
Install a water filter or air dryer if
application requires dry air.
Safety Guidelines
This manual contains information that is
very important to know and understand.
This information is provided for SAFETY
and to PREVENT EQUIPMENT PROBLEMS.
To help recognize this information,
observe the following symbols.
Danger indicates
DANGER
!
an imminently
hazardous situation which, if not
avoided, WILL result in death or serious
injury.
Warning indicates
WARNING
!
a potentially
hazardous situation which, if not
avoided, COULD result in death or
serious injury.
Caution indicates a
CAUTION
!
potentially
hazardous situation which, if not
avoided, MAY result in minor or
moderate injury.
Notice indicates
NOTICE
important
information, that if not followed, MAY
cause damage to equipment.
Unpacking
After unpacking the unit, inspect
carefully for any damage that may have
occurred during transit. Make sure to
tighten fittings, bolts, etc., before
putting unit into service. In case of
questions, damaged or missing parts,
please call 1-800-543-6400 for customer
REMINDER: Keep your dated proof of purchase for warranty purposes! Attach it to this manual or file it for safekeeping.
© 2002 Campbell Hausfeld/Scott Fetzer
Oilless
Compressors
DO NOT RETURN THE
PRODUCT TO THE
STOP!
RETAILER!
Record the Model No., Serial No. and
date of purchase located on the base
below the pump in the space below.
Model No. ____________________
Serial No. ____________________
Date of purchase _________________
Retain these numbers for future
reference.
assistance or call the nearest Campbell
Hausfeld Authorized Service Center.
A listing of service center locations is
enclosed. Have the serial number,
model number, and parts list (with
missing parts circled before calling.)
Do not operate
WARNING
!
unit if damaged
during shipping, handling or use.
Damage may result in bursting and
cause injury or property damage.
General Safety
Information
Since the air compressor and other
components (material pump, spray
guns, filters, lubricators, hoses, etc.)
used, make up a high pressure
pumping system, the following safety
For parts, product & service information
visit www.chpower.com
DANGER
!
Breathable Air Warning
This compressor/pump is not
equipped and should not be used
"as is" to supply breathing quality
air. For any application of air for
human consumption, the air
compressor/pump will need to be
fitted with suitable in-line safety
and alarm equipment. This
additional equipment is necessary
to properly filter and purify the air
to meet minimal specifications for
Grade D breathing as described in
Compressed Gas Association
Commodity Specification G 7.1 -
1966, OSHA 29 CFR 1910. 134,
and/or Canadian Standards
Associations (CSA).
DISCLAIMER OF WARRANTIES
In the event the compressor is used
for the purpose of breathing air
application and proper in-line
safety and alarm equipment is not
simultaneously used, existing
warranties shall be voided, and
Campbell Hausfeld disclaims any
liability whatsoever for any loss,
personal injury or damage.
precautions must be observed at all
times:
1. Read all manuals
included with this
product carefully. Be
thoroughly familiar
with the controls and
the proper use of the equipment.
2. Follow all local electrical and safety
codes as well as in the US, National
Electrical Codes (NEC) and Occupational
Safety and Health Act (OSHA).
IN606800AV 11/02
FP2040
Need
Assistance?
Call Us First!
1-800-543-8622
MANUAL

Publicité

loading

Sommaire des Matières pour Campbell Hausfeld FP2040

  • Page 1 1-800-543-6400 for customer REMINDER: Keep your dated proof of purchase for warranty purposes! Attach it to this manual or file it for safekeeping. IN606800AV 11/02 © 2002 Campbell Hausfeld/Scott Fetzer For parts, product & service information visit www.chpower.com...
  • Page 2 Oilless Compressors General Safety Installation DANGER Information (Continued) LOCATION Never attempt to repair or modify a tank! It is extremely important to use the 3. Only persons well acquainted with Welding, drilling or any compressor in a clean, well ventilated these rules of safe operation should other modification will weaken the area where the surrounding air...
  • Page 3 FP2040 Installation Handle (Continued) DANGER ON/OFF Switch Improper use of grounding plug can result in a possible risk of electrical shock! Regulator Do not use a DANGER grounding adapter with this product! 2. If repair or replacement of cord or plug...
  • Page 4 Oilless Compressors Operation (Continued) MOISTURE IN COMPRESSED AIR Moisture in compressed air will form into droplets as it comes from an air 7. Attach chuck or other tool to open compressor pump. When humidity is high or when a compressor is in continuous end of hose.
  • Page 5 FP2040 Troubleshooting Chart Symptom Possible Cause(s) Corrective Action Compressor will not run 1. No power or switch in OFF position 1. Make sure compressor is plugged in and switch is ON 2. Blown fuse 2. Disconnect compressor from power source then remove pump shroud.
  • Page 6 Oilless Compressors Troubleshooting Chart (Continued) Symptom Possible Cause(s) Corrective Action Compressor runs 1. Excessive air usage, compressor too 1. Decrease usage or purchase unit with higher air continuously and air small delivery (SCFM) output is lower than 2. Air leaks in piping (on machine or in 2.
  • Page 7 FP2040 For Replacement Parts, Call 1-800-543-6400 Please provide following information: -Model number -Serial number (if any) -Part description and number as shown in parts list Address parts correspondence to: The Campbell Group Attn: Parts Department 100 Production Drive Harrison, OH 45030 U.S.A.
  • Page 8 8. RESPONSIBILITIES OF PURCHASER UNDER THIS WARRANTY: A. Provide dated proof of purchase and maintenance records. B. Portable compressors or components must be delivered or shipped to the nearest Campbell Hausfeld Authorized Service Center. Freight costs, if any, must be borne by the purchaser.
  • Page 9 En cas de dommage ou de pièces détachées (pompe, pistolets, filtres, MÉMENTO: Gardez votre preuve datée d'achat à fin de la garantie! Joignez-la à ce manuel ou classez-la dans un dossier pour plus de sécurité. © 2002 Campbell Hausfeld/Scott Fetzer IN606800AV 11/02 9 Fr...
  • Page 10 Compresseur Sans Huile Généralités sur la Installation DANGER Sécurité (Suite) ENDROIT Ne jamais essayer de réparer ou de modifier un réservoir! Le Il est très important d’utiliser le 3. Seules les personnes bien familiarisées soudage, perçage ou autre modifications compresseur dans un endroit propre et avec ces règles d’utilisation doivent peuvent affaiblir le réservoir et peuvent bien ventilé...
  • Page 11 FP2040 Installation S’il n’est pas possible d’atteindre les LUBRIFICATION (Suite) conditions ci-dessus ou s’il y a un Ce produit est “sans-huile” et n’exige DANGER déclenchement du protecteur de pas d’huile pour fonctionner. courant à maintes reprises, il peut être L’usage incorrect d’une fiche RODAGE nécessaire de faire fonctionner le...
  • Page 12 Compresseur Sans Huile Fonctionnement L’HUMIDITÉ DANS L’AIR COMPRIMÉ (Suite) L’humidité dans l’air comprimé forme des goutelettes en arrivant de la pompe Le compresseur se remettra en du compresseur. Si l’humidité est élevée ou si le compresseur est utilisé marche à une pression réglée continuellement, cette humidité...
  • Page 13 FP2040 Guide de Dépannage Symptôme Cause(s) Possible(s) Mesures Correctives Le compresseur ne 1. Manque d’alimentation ou 1. S’assurer que le compresseur soit branché et que fonctionne pas interrupteur dans la position hors l’interrupteur soit ON (en marche) circuit (OFF) 2. Fusible sauté...
  • Page 14 Compresseur Sans Huile Guide de Dépannage (Suite) Symptôme Cause(s) Possible(s) Mesures Correctives Perte de pression quand 1. Robinet de vidange desserré 1. Serrer le compresseur s’arrête 2. Fuite de clapet 2. Démonter le montage de clapet, nettoyer ou remplacer 3. Connexions desserrées au manostat, 3.
  • Page 15 FP2040 Pour Pièces de Rechange, appeler 1-800-543-6400 S’il vous plaît fournir l’information suivant: Correspondance concernant les pièces : -Numéro du modèle The Campbell Group -Numéro de série (si applicable) Attn: Parts Department -Description de la pièce et son numéro sur la liste de pièces 100 Production Drive Harrison, OH 45030 U.S.A.
  • Page 16 2. GARANTIE ACCORDÉE PAR (GARANT): Campbell Hausfeld/Scott Fetzer Company, 100 Production Drive, Harrison, Ohio, 45030, Téléphone: (800) 543-6400 3. BÉNÉFICIAIRE DE CETTE GARANTIE (ACHETEUR): L’acheteur original (sauf en cas de revente) du produit Campbell Hausfeld. 4. PRODUITS COUVERTS PAR CETTE GARANTIE: N’importe quel compresseur d’air Campbell Hausfeld.
  • Page 17 ______________________ de seguridad y alarma, todas la garantías se hay una situación inmediata que LE Fecha de Compra ____________________ anularán y la compañia Campbell Hausfeld OCASIONARIA la muerte o heridas de no asumirá NINGUNA responsabilidad por gravedad. Guarde estos números para pérdidas, heridas personales o daños.
  • Page 18 Compresores Sin Aceite compresor. Coloque el compresor lo Informaciones determinar la razón. Generalmente, la más lejos posible del área de trabajo, vibración excesiva se debe a una falla. Generales de Seguridad para minimizar la acumulación de 11. Para reducir el peligro de incendio, (Continuación) residuos en el compresor.
  • Page 19 FP2040 voltios bajo las siguientes condiciones: Instalación que éste se regrese al cabezal. a. Ningún otro artefacto eléctrico o Mango - Diseñado para mover el (Continuación) luces estén conectados al mismo compresor. circuito. Llave de drenaje - Esta válvula está...
  • Page 20 Compresores Sin Aceite Funcionamiento HUMEDAD EN EL AIRE COMPRIMIDO La humedad que se acumula en el aire comprimido se convierte en gotas a medida que (Continuación) sale del cabezal del compresor de aire. Cuando el nivel de humnedad es muy alto o cuando el compresor ha estado en uso continuo por mucho tiempo, ésta se acumulará...
  • Page 21 FP2040 Guía de diagnóstico de averías Problema Posible(s) Causa(s) Acción a tomar El compresor no 1. No hay corriente eléctrica, o el 1. Cerciórese de que el compresor esté conectado al funciona interruptor está en OFF (apagado) tomacorriente y el interruptor esté en ON (encendido) 2.
  • Page 22 Compresores Sin Aceite Guía de diagnóstico de averías (Continuación) Problema Posible(s) Causa(s) Acción a tomar La presión del tanque 1. Llave de drenaje floja 1. Ajuste cae cuando se apaga el 2. Válvula de retención con fugas 2. Reemplace cabezal compresor 3.
  • Page 23 FP2040 Para Ordenar Repuestos Sírvase Llamar al Distribuidor Mas Cercano A Su Domicilio Sírvase darnos la siguiente información: Puede escribirnos a: -Número del modelo The Campbell Group / Attn: Parts Department -Número de Serie (de haberlo) 100 Production Drive -Descripción y número del repuesto según la lista de repuestos Harrison, OH 45030 U.S.A.
  • Page 24 Estándard (Standard Duty) - Un año, Productos Resistentes (Serious Duty) -Dos años, Productos Robustos (Extreme Duty) - Tres años. 2. QUIEN OTORGA ESTA GARANTIA (EL GARANTE: Campbell Hausfeld / The Scott Fetzer Company 100 Production Drive, Harrison, Ohio 45030 Teléfono: (800) 543-6400 3.