Ground-Fault Protection - Pentair Raychem QuickStat-TC Manuel D'installation Et D'utilisation

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

Thermostat Controls and Display
The following figure shows the thermostat controls. The thermo-
stat has three temperature control modes:
• AF mode: (Default mode) Controls the system based on the
ambient air temperature and ensures that the floor tempera-
ture does not exceed the desired limits using an external floor
temperature sensor
• F mode: Controls the floor temperature using an external floor
sensor
• A mode: Controls the system based on the ambient air temper-
ature (does not use floor sensor)
ON/OFF switch
1
and GFCI reset
2
Appears when the
setpoint is displayed
Date and time
settings
Percentage of
heating time
3
Program button
Program
clear button
Mode selection
/ program exit
Backlight button
1
Place the switch in Standby to cut power to the heater when
not in use (e.g., in the summer). This will not affect the time and
temperaturesettings.
2
To reset the ground-fault protection, switch the thermostat to
Standby and back to On.
3
The thermostat displays the percentage of heating time required
to maintain the desired temperature. For example,
when heating is activated 40 percent of the time.
Display
1 to
% of heating time
24%
4
GFI appears when the ground-fault protection has tripped.
The display illuminates for 12 seconds when the backlight button
is pressed. When either of the
display also illuminates. The setpoint temperature appears for 5
seconds, then the actual measured temperature is displayed.
Date and Time Setting
The first time you power up the thermostat, the time and date will
flash and must be set.
1. Press the Hour button to set the hour.
2. Press the Min button to set the minutes.
3. Press the Day button to set the day.
4. Press Mode/Ret to exit.
Daylight Savings Time
The QuickStat-TC can automatically adjust for Daylight Savings
Time. When this function is enabled, the thermostat switches to
Daylight Savings Time on the second Sunday of March and to nor-
mal time on the first Sunday of November.
THERMAL BUILDING SOLUTIONS
GFCI test button
Time and day
display
Temperature
display
Mode
display
Preset temperature
indicator
Temperature control
mode indicator
Ground-fault
indicator
4
Temperature
preset buttons
Period display
Temperature
adjustment buttons
is displayed
25 to
50 to
75 to
49%
74%
99%
buttons are pressed, the
EN-RaychemQuickStatTCthermostat-IM-H58517      10/14
Note: This function is disabled (default setting) when the
clock loses its setting
To enable Daylight Savings Time:
1. Press and hold the Day button for 3 sec-
onds until DLS appears on the screen.
2. Press the up/down
between On (enabled) and Off (disabled).
3. Press the Day button. The year setting is
displayed.
4. Use the up/down
current year.
5. Press the Day button. The month setting is
displayed.
6. Use the up/down
current month.
7. Press the Day button. The date setting is
displayed.
8. Use the up/down
current date.
9. Press Mode/Ret to exit.

Ground-Fault Protection

he QuickStat-TC has a built-in GFCI (5 mA trip level). This
T
protects users against risks of electrocution by cutting off the
power to the floor heating system when the leakage current
exceeds 5 mA. If a ground-fault has occurred, the TEST light
on the top of the thermostat will illuminate red and GFI will
appear on the screen.
Testing the GFCI
Users should test the GFCI after the installation of the QuickNet
or CeraPro floor heating system is complete to ensure that the
ground-fault protection is in working order. Users should test the
GFCI on a monthly basis thereafter.
1. The GFCI can only be tested if the thermostat has a heating
demand. Increase the setpoint temperature above the current
measured temperature. Wait several seconds to allow the
100%
thermostat to adjust to the new set point and the heating
symbol
appears.
2. Press the TEST button.
The test is successful if the TEST light on top of the thermostat
illuminates red and GFI appears on the screen.
The test has failed if the TEST light on top of the thermostat does
not illuminate red. In this case, turn the power off to the floor
heating system and check the installation of the thermostat.
Resetting the GFCI
If the GFCI has tripped, reset it by switching the thermostat to
Standby and back to On. The TEST light on top of the thermostat
will go off.
If the GFCI trips in normal operation without pressing the TEST
button, there could be a ground-fault. To check whether it is a
ground-fault or nuisance tripping, reset the GFCI. If the GFCI does
not trip after the reset, it was nuisance tripping and the system is
functioning properly. If the GFCI trips again after the reset, there
is a ground-fault. The user should contact a qualified electrician to
troubleshoot the issue.
buttons to toggle
buttons to set the
buttons to set the
buttons to set the
3 / 6

Publicité

Table des Matières
loading

Table des Matières