G Operating instructions
Ceiling-mounted motion detector 360°
Item no. 1296308
Intended use
The PIR sensor integrated in the ceiling-mounted motion detector responds to tem-
perature changes within the detection range, e.g. if a person, a large animal or a car
enters the detection range.
For this reason, the ceiling-mounted motion detector can be used for monitoring ent-
rances, staircases, etc.
The ceiling-mounted motion detector's output can be used, for example, for controlling
a light or another powered device.
Always observe the safety instructions included in these operating instructions. Ple-
ase read the operating instructions carefully and keep them.
Any use other than that described above could lead to damage to this product and
involves the risk of short circuits, fire, electric shock, etc. No part of the product may
be modified or converted!
This product complies with the applicable national and European requirements. All
company and product names included are trademarks of their respective owners. All
rights reserved.
Delivery contents
• Ceiling-mounted motion detector
• Operating instructions
Explanation of symbols, inscriptions
The lightning symbol in a triangle is used to alert you to potential risks for
personal injury, such as electric shock.
This symbol indicates specific risks associated with handling, function and
use.
The "arrow" symbol indicates special tips and operating information.
The product is constructed according to Protection Class II.
This product is only to be installed and used indoors in dry conditions. The
product must not get damp or wet as there is danger of a fatal electric
shock!
Safety instructions
R ead the complete operating manual carefully before using the product as
it contains important information about the correct installation and opera-
tion.
T he warranty will be void in the event of damage caused by failure to ob-
serve these safety instructions! We are also not responsible for any conse-
quential damage!
W e do not assume any liability for damage to property or personal injury
caused by improper use or disregard of safety instructions! The warranty
will be void in such cases!
Caution!
T he product may be installed only by a qualified technician (e.g. electrici-
an) who is familiar with the relevant regulations (e.g. VDE, German electri-
cal wiring regulations)!
I mproper work carried out at the mains voltage endangers not only your life
but also the life of others!
I f you do not have the expertise required for the installation, do not install it
yourself but entrust the work to a qualified electrician.
• Unauthorised conversion and/or modification of the product is not allo-
wed for safety and approval reasons (CE).
• The product is not a toy and must be kept out of the reach of children!
There is danger of a life-threatening electric shock!
• The product may be operated only on the mains voltage (see section
"Connection" and "Technical Data"). Never try to operate the product at
another voltage, as this will cause its destruction.
• An isolator that disconnects all poles from the mains voltage (e.g. RCD)
must be provided at the installation site.
• This product is to be installed and used only in dry conditions indoors. The
product must not get damp or wet as there is danger of a fatal electric
shock!
• Only use the product when it is securely installed and steady. Never install /
operate it in vehicles.
• Do not use the ceiling-mounted motion detector in rooms or under adver-
se am-bient conditions where combustible gases, vapours or dust are or
may be present! There is a risk of explosion!
• The product must not be exposed to extreme temperatures, strong vibra-
tions or heavy mechanical stress.
• If it can be assumed that safe operation is no longer possible, the device
must be turned off and precautions are to be taken to ensure that it is not
used unintentionally. After this, arrange for an expert to check the pro-
duct.
A safe operation can no longer be assumed if:
- the product shows visible signs of damage
- The product does not work at all or works poorly (where there is flicke-
ring light, leaking smoke or a smell of burning, audible crackling noises,
or discolouration to the product or to adjacent surfaces)
- the product was stored under unfavourable conditions
- it was exposed to heavy loads during transport
• Do not leave packaging material carelessly lying around, since it could
become a dangerous plaything for children.
• In commercial institutions, the accident prevention regulations of the
Employer's Liability Insurance Association for Electrical Systems and
Operating Facilities are to be observed!
• If you have any questions that are not answered in this manual, please
contact our technical service or another specialist.
Preparations for installation
Please refer to the section "Safety instructions"!
• Keep a minimum distance of at least 1m from lights and other heat sources, in order
to avoid malfunctions or switching errors.
Are the light switches too close to the ceiling motion detector, the ceiling
motion detector switching on again immediately may happen because it re-
cognizes the cooling process as a heat change.
If this is the case it is due to the position of the ceiling motion sensor and the
lights, then we suggest that you limit the detection area by placing a strip of
opaque tape on the side of the ceiling motion detector facing towards the
light switches.
• Only install the ceiling-mounted motion detector on a solid, stable surface.
• The ceiling-mounted motion detector can be installed indoors underneath a hori-
zontal surface (e.g. room ceiling). Alternatively, it can also be mounted on a wall,
depending on the monitored area.
• The ceiling-mounted motion detector must be installed only when it is voltage-free.
Turn off the mains supply by switching off the appropriate circuit breaker or by
pulling out the fuse. Secure it against unauthorised reconnection, e.g. with a danger
sign.
Furthermore, turn off the earth leakage circuit breaker to disconnect all the poles
from the mains voltage.
• Check the mains connection for absence of voltage using a suitable meter.