EN
11.1.f - Replacing the squeegee rub-
ber blades (Fig. 19)
When it becomes clear that drying the floor
is difficult or traces of water remain on the
floor, it is necessary to check the wear on the
squeegee rubber blades (1):
-
Remove the squeegee unit (1) as indicat-
ed in the "Cleaning the squeegee" para-
graph.
-
Loosen the finned nuts (2) and remove
the rubber blades (3).
N.B.:
When the rubber blades (3) are worn on one
side, on one occasion they may be turned
over.
-
Replace or turn over the rubber blades
(3) without inverting them.
-
Replace all the components in reverse
order.
N.B.:
It is possible to have two types of rubber
blade.
Para rubber blades for all types of floor and
polyurethane rubber blades for mechanical
workshop floors which are dirty with oil.
11.1.g - Replacing the fuses (for BC
version only)
(Fig. 20)
WARNING:
Replace the blown fuse with one with the
same amperage.
-
Unscrew the two knobs (4) and remove
the cover (5) to access the fuses (6), (7),
(8).
Fuse 6 - Red 40A
Main machine protection.
Fuse (7) - Yellow 20A
Aspirator motor protection
Fuse (8) Green 30A
Brush rotation motor protection.
-
Replace the cover (5), proceeding in re-
verse order.
5
6
EN-22
3
2
7
8
1
Fig. 19
4