Endress+Hauser Memograph M RSG40 Mode D'emploi page 34

Masquer les pouces Voir aussi pour Memograph M RSG40:
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

Commissioning and operation
!
!
"
34
5.4.3
Procedure for setup via interface and PC software supplied:
Note!
In order to be able to use this function, the unit must already be created in the PC database or has
to be created beforehand.
1.
Connect the unit interface (RS232 / RS485, USB or Ethernet) to the PC.
2.
Start the PC software and create a new unit in the PC database:
- Select "Unit -> Display/change unit setup/Add new unit"
- Select "Unit -> Add new unit"
- Enter unit identifier. To transmit the unit setup select the corresponding unit interface.
Confirm with "Next". Select the corresponding interface parameters (must match the settings
for communicating at the device). Confirm with "Next". A summary of the information on the
new unit is displayed. When you click "OK", a connection is established to the unit and the
new unit is created in the PC database.
3.
Adjust the unit settings and select "Finished -> Send setup to unit". The new setup parameters
are automatically transferred to the unit.
4.
Finally, the unit settings should be saved in the unit database. Select "Finished -> Save setup
in unit database".
5.4.4
Setup via SD card
Save the unit settings on the PC onto the SD card using the PC software supplied. This setup file
can then be imported into the unit.
Note!
In order to be able to use this function, the unit must already be created in the PC database or has
to be created beforehand. In addition, there has to be an SD card slot on the PC.
Caution!
Never remove the SD card from the unit without previously launching the function "Extras –> SD
card –> Remove safely" as data could be lost otherwise.
Procedure for setup using an SD card:
1.
Copy setup to SD card:
- Insert a formatted SD card into the unit.
- In the Extras menu, select "SD card -> Save setup".
– In the Extras menu, select "SD card –> Remove safely".
– Remove the SD card from the unit and insert it into the SD card slot at the PC.
2.
Start the PC software and create a new unit in the PC database:
– Select "Unit –> Display/change unit setup/Add new unit"
– Select "Unit –> Add new unit"
– Enter unit identifier. Select "Parameter file from a data source (e.g. diskette, ATA Flash, CF,
SD)" to transmit the unit setup. Confirm with "Next". Select the corresponding unit parameter
file (*.rpd) from the SD card. Confirm with "Next". A summary of the information on the new
unit is displayed. When you click "OK", the new unit is created in the PC database.
3.
Adjust setup in the PC program and save in the associated database:
- Adjust the unit settings.
– Select "Finished –> Save setup in unit database". The new setup parameters are saved in the
PC database. Transfer the new SETUP file to the SD card in your PC: select "Finished –> Create
setup data carrier (diskette/ATA flash/CF/SD)" and select the suitable drive.
– Remove the SD card from the slot in the PC and insert it into the unit.
4.
Read in new setup directly at the unit:
– In the Extras menu, select "SD card –> Load setup". To remove the SD card, select "SD card
–> Safe removal" in the Extras menu. Repeat these steps to configure additional units with this
setup.

Publicité

Table des Matières
loading

Table des Matières