RESET (Resetting to the factory settings)
1. Disconnect the lamp from
the mains by:
– pulling the plug or
– disconnecting the fuse.
35 seconds have expired when the lamp has flashed altogether 10 x. The factory setting is now
restored. The RESET is acknowledged by the lamp and the LED in the sensor flashing 10 times
after the button has been released.
Confirmation after releasing
the button
Lamp flashes 1 x
Lamp flashes 2 x
Lamp flashes 3 x
Lamp flashes 4 x
Lamp flashes 5 x
Lamp flashes 6 x
Lamp flashes 7 x
Lamp flashes 8 x
Lamp flashes 9 x
Lamp flashes 10 x
2. Keep the button depressed
and connect the lamp with the
mains.
Remarks
Lamp reacts only to motion
Lamp controls only the luminous intensity
Light and motion sensor switched off
Light value does not need to be stored
via the button
Only motion detector switches off. Dimming occurs
to max. 1% via light sensor
As under point 5, but without motion sensor
Semi-automatic, must be switched on manually
in the morning
As under point 7, but does not switch off via light
sensor, goes to 1%, must be switched on manually
Lamp must be switched on manually, motion
detector active after that
3. Release the button after 35s
Application
Use in galleries, reception
Strip lights switched centrally,
open plan offices
As dimmer module, touch dim
Belux mode
Customer sees that light is
switched on
Customer sees that light is
switched on, switched off com-
pletely via button
Office area, individual stations
Office area, individual stations
Stairway reception
Reset / delivery state
everything on