Operation
Operation
Mode
The brightness control and the automatic motion detection can be switched on and off individually.
In the delivery state the automatic motion detection and the brightness control are active
(see Mode 10 in the table below).
Changing the Mode
1. For the time that is
assigned to the new
mode, refer to the table
illustrated.
The expiry of the individual time intervals is signaled in each
case by the lamp and the LED in the sensor flashing one time.
Mode
Motion Detection
1
active
2
off
3*
off
4
active
5
active
6
off
7
active, no automatic
switch-on with motion
8
active, no automatic
switch-on with motion
9
active, no automatic
switch-on with motion
10
active
14
2. Disconnect the lamp from the
mains by:
– pulling the plug or
– disconnecting the fuse.
Brightness Control
off
active
off
active, setpoint corre-
sponds to last selected
dimmer setting
active, no switch-off
with daylight
active, no switch-off
with daylight
active
active, no switch-off
with daylight
off
active
3. Keep the button depressed
and connect the lamp with the
mains.
4. Release the button after the
timespecifiedinthetable.
Actuation Time
Signaling after expiry
of time
6 s
1
st
9 s
2
nd
12 s
3
rd
15 s
4
th
18 s
5
th
22 s
6
th
25 s
7
th
28 s
8
th
31s
9
th
35 s
10
th
flashing of lamp
flashing of lamp
flashing of lamp
flashing of lamp
flashing of lamp
flashing of lamp
flashing of lamp
flashing of lamp
flashing of lamp
flashing of lamp