OBJ_BUCH-0000000244-001.book Page 13 Friday, December 11, 2015 8:33 AM
Changing the tool (FMT250QSL (**)).
Before using, sharpen used and even new cut-
ter blades with a sharpening stone.
The symptom for worn blades is a clearly
increased feed force at lower working prog-
ress.
Do not switch the power tool
CAUTION
on while the clamping lever is
open. Otherwise there is danger of crushes or
contusions to the hand and fingers.
Do not actuate the clamping
CAUTION
lever while the power tool is
running. Otherwise there is danger of injury.
Inserting the application tool (figure 3).
Clean the tool holder and the application tool.
In the starting position, the clamping jaws in
the tool holder are together. In this position,
the application tool can be clipped-in easily.
Do not reach into the area of
CAUTION
the clamping jaws. Otherwise
there is danger of crushes or contusions to
the fingers.
Do not operate the power tool
CAUTION
with open clamping jaws and
without an application tool! This could dam-
age the power tool.
When the clamping jaws are
CAUTION
open before the application
tool is inserted, pivot the clamping lever
toward the front and then back again. The
clamping jaws are closed now. The application
tool can be inserted.
Fig. 3
1.
2.
3.
en
13