BRS-FP/BRS-FPi
1
10
9
8
1
Set of clamping jaws *
2
Reamer holder
3
Pneumatic connection
4
Electrical connection
Fig. 3
Torch cleaning station
NOTICE
• * These equipment parts must be adapted to the gas nozzle and torch geometry.
6 Commissioning
Risk of injury due to unexpected start-up
The following instructions must be adhered to throughout all maintenance, servicing, assembly,
disassembly and repair work:
• Switch off the power source.
• Close off the gas supply.
• Close the compressed air supply.
• Disconnect all electrical connections.
• Switch off the entire welding system.
BAL.0028 • 2017-03-10
7
5
Aluminum housing
6
PCB
7
Covering hood
8
Pneumatic motor
DANGER
6
5
6 Commissioning
2
3
4
9
Guide block
10 Reamer *
EN - 11