3 Product description
Weight
Dimensions LxWxH
Protection type in accordance with DIN 40050
Protection class in accordance with DIN 51106
Tab. 2
General information
Compressed air connection
Inner width
Nominal pressure
Working pressure
Quality of compressed air (ISO 8573-1:2010)
Tab. 3
Pneumatic distributor block
Operating voltage
Permitted range
Permissible residual ripple
Input (START)
Output (READY)
Tab. 4
Electrical system
NOTICE
• To guarantee the maximum power and useful life of the torch cleaning station, operate it with clean,
Pneumatic motor
Idle speed
Load speed
Nominal flow air consumption
Air consumption
Tab. 5
Cleaning unit BRS-FP/BRS-FPi
3.2 Abbreviations
BRS
TCP
Tab. 6
Abbreviations and term definitions
Unit of measurement in drawings or diagrams
Tab. 7
Dimensions
EN - 8
lubricated air.
Approx. 10 kg
230x208x380
IP 21
I
G1/4"
ø
Min.
8 mm
6 bar
6 - 8 bar
Min. class 4
24 V DC/15 W
20 - 30 V DC
Vss < 10%
START + or START - can be selected (depending on the connector)
READY + or READY- can be selected (depending on the connector)
Short-circuit -proof, overload-protected
Approx. 850 rpm
650 rpm
325 rpm
Approx. 600 l/min
Approx. 380 l/min
Torch cleaning station (TCS)
Tool center point
Millimeter [mm]
BRS-FP/BRS-FPi