System installation instructions

1
System 0020235577
VWS 36/4.1 230V with VWZ MEH 61 and VRC 700
Caution.
Risk of material damage caused by incomplete installation.
This drawing is a basic representation and does not replace complete planning. This drawing does not
contain all of the required valves and safety fittings for a complete installation.
Observe the applicable national and international laws, standards and guidelines.
When planning, installing and subsequently operating this system, you must observe all the install-
ation and operating instructions available for the product, the relevant accessories and for any other
component.
The responsibility for design lies with the responsible company.
1.1
Basic hydraulic diagram 0020235577
1c
Heating/domestic hot water back-up boiler
2
Heat pump
3e
Circulation pump
5
Monovalent domestic hot water cylinder
8b
Potable water expansion relief valve
Safety group – drinking water connection
8c
0020251822_01 System installation instructions
System 0020235577 1
8e
Heating diaphragm expansion vessel
Diaphragm expansion vessel – potable water
8f
9a
Single-room temperature control valve (thermo-
static/motorised)
9d
Bypass valve
9h
Filling/draining cock
9j
Tamper-proof capped valve
1