5.3
Mounting the product
Verify that the permissible ambient temperature is not exceeded.
Verify that the product is not mounted the product on top of or next to a
non-insulated boiler part, above opening dampers at furnaces or to the
flue gas pipe.
Verify that the float housing points vertically to the top.
1. Mount the product to the sheet metal boiler wall using the enclosed tap-
ping screws.
2. Use the bracket as a template when drilling the holes (Ø 3 mm).
Verify that suitable oil hoses (as per DIN 4798-1) for connection to the oil
pump are used.
Mounting
Verify that an oil filter is installed in
3. Connect the burner hoses to the
A
The connection to the filter "connec-
B
tion T" (b) can be made with the
optional, enclosed hose G
C
a G
D
the supply line upstream of the
product.
two threaded sockets R and V (A).
- The tightening torque is
25 ±5 Nm.
3
(D) union nut.
/
8
Flow-Control
EN
1
(C) and
/
4
15