Technical data

Operating voltage ......................................................230 V/AC (+/- 10%) 50/60 Hz
Output voltage ..........................................................0 -36 V/DC
Output current ..........................................................0.01 - 10 A
Output power ............................................................max. 1440 VA
Response for a load change 0-100% ........................Voltage: ±(0.05% + 10 mV)
Current: ±(0.6% + 50 mA)
Residual amplitude....................................................<10 mVrms (rms = effective)
Protectoin class 1
Mains connection ......................................................Low-power device installation plug, IEC C14
Mains fuse ................................................................Fuse machine, slow-trigger 10A/250 V
Dimensions (W x H x D) ............................................483 x 88 x 455 (mm)
Weight ......................................................................20 kg
Operating temperature ..............................................0°C to +40°C
Rel. air humidity ........................................................max. 85%, non-condensing