children to play with the appliance. The cleaning
and maintenance to be performed by the user must
not be performed by unsupervised children.
• Do not allow comfort or familiarity with the product
(due to using it repeatedly) to substitute strict
compliance with the safety regulations. Stay alert,
pay attention to what you are doing and use
common sense when operating the appliance.
• Do not use the equipment when you are tired or
under the influence of drugs, alcohol or any other
medication. If you use the tool in an unsafe or
incorrect way, you may suffer personal injury or
material damage.
• The models cited in the manual have been
designed for use in hotels, restaurants, catering
and commercial applications.
• The manufacturer is not responsible when the
product is used incorrectly or differently than the
use mentioned above. Such as, sanitary use,
chemical use, use in explosive atmospheres...
• If you wish to use an accessory, it must specifically
be for the model in question and carry the SAMMIC
brand. The user is responsible for any incident
provoked by an accessory that does not carry the
SAMMIC brand.
ELECTRICAL INSTALLATION
The machines are supplied for operation on 230V/50-60Hz/1~ or
120V/50-60Hz/1~. Prepare a single-phase wall-mounted socket with a
residual current and circuit breaker of 10 A.
ASSEMBLY OF THE BLENDER AND MIXER ARM
Picture 10
With the blender unplugged, guide the arm attachment (2) into the
motorised body (1) so that the "arrow" symbol on the arm matches the
"open padlock" symbol on the motor block. Twist the arm clockwise until
the "arrow" matches the "closed padlock" symbol and you notice a "click"
which indicates that it is firmly attached against the restraint system.
To remove, proceed in the opposite manner (10).
ASSEMBLY OF THE MIXER ARM STIRRERS (MODELS
MB AND B)
To assemble, insert the stirrer bushing into the hole in the geared motor
by turning and pushing until it reaches the end. To remove, pull firmly on
the stirrer until it separates from the geared motor.
OPERATION
Introduce the appliance's arm into the container, a maximum of up to
2/3 of the length of the arm, marked with "MAX" (7). Never exceed this
mark. For optimal operation, avoid touching the bottom of the container.
To avoid splashes from entering the motor block, we recommend that
the tilt of the appliance does not exceed 30° (6).
The appliance has a pilot light (3) and when said light is on, this means
that it is connected. Handle the appliance carefully whenever the pilot
light (3) is on, as it will start operating if the "On" button (5) is pressed.
To stop it again, release the button (5).
The speed of the blade can be changed using the adjustment control (4).
When you have finished using it, always disconnect the plug from the
wall socket.
If overheating occurs due to an overload in use, motor blockage... the
thermal protector protects the motor and stops it. Wait for the blender to
cool before turning it on again.
CLEANING AND HYGIENE. WARNINGS
- To avoid electric shocks that can cause serious personal injury, unplug
the appliance before cleaning.
- This appliance is fitted with sharp blades (8). Handle them with care.
- Do not use the following products: abrasive cleaning products (such as
ammonia, bleach, etc.) solvents, metal scourers to scrub, gritty detergent.
These products may scratch, cut and damage the metal and plastic
surfaces of the appliance.
CLEANING PROCEDURE
Cleaning the blender/beater arm (2), after each use is absolutely
necessary, as well as checking the condition of the lower seals (9). If
you see any signs of deterioration in the seal, contact the authorized
repair service.
After each use, place up to 2/3 of the length of the blender arm in
a recipient containing hot water (35-45 ºC) and switch on for a few
seconds.
The tube and the blade must be washed with hot water (35-40º C) and
an Ivory Liquid type of multi-purpose liquid detergent in a proportion
of 1 measure of detergent per 10 measures of water, leaving them
submerged for 30 minutes. Rinse the soap residues from the stirrers
with hot water (35-45ºC) as explained in the section dealing with rinsing.
The motor block (1) should only be cleaned with a damp cloth. Under
no circumstances should water enter into the motor block. If water
accidentally penetrates inside the motor block, do not connect the
machine again and contact an authorized technical service.
DESINFECTION PROCEDURE
After cleaning, remove the blender/beater arm from the models where
this option is available. Neither the blender arm (2), nor the beater arm
nor the beater arm reducer unit must be submerged in water.
The blender arm, the blade and the stirrers must be disinfected by using
hot water (35-45º C) and a multi-purpose chlorinated disinfectant with
a maximum concentration of 5.25 % of available chlorine. Prepare the
disinfectant solution by mixing a ratio of 14 cm3 of the multi -purpose
chlorinated disinfectant for each gallon US (3.785 liters) of water. Never,
the solution cannot exceed 200 parts per million (ppm) of available
chlorine.
To disinfect the blender arm and the blade, first using a soft cloth
moistened with the disinfectant solution, clean any food residues that
may remain. Continually, place up to 2/3 of the length of the blender arm
in a recipient containing the disinfectant solution (5 liters, depending on
the recipient used) for at least 30 minutes totally covered. Rinse the soap
residues from the blender arm and the blade with hot water (35- 45ºC)
9
- 9 -
EN