INSTALLATION INSTRUCTIONS (CONTINUED)
Improper installation of the grounding plug is able to result in a risk of electric
shock. When repair or replacement of the cord or plug is required, do not connect
the grounding wire to either flat blade terminal. The wire with insulation having an outer surface that
is green with or without yellow stripes is the grounding wire.
Never connect green (or green and yellow) wire to a live terminal.

Extension Cords

1. The air compressor should be located where it can be directly plugged into an outlet. An extension cord
should not be used with this unit.
2. To avoid loss of power and overheating, additional air hose must be used to reach work area instead of
extension cords.
Minimum Gauge of Extension Cords for 120V Unit
Motor Amp Rating
Range
10-12 amp
12-14 amp
14-16 amp

Thermal overload protector

This compressor is equipped with a manual reset thermal overload protector
which will shut off motor if it becomes overheated.
If thermal overload protector shuts motor OFF frequently look for the following causes:
1. Low voltage.
2. Wrong gauge wire.
3. Clogged air filter.
4. Lack of proper ventilation.
5. Unit is being used with an extension cord.
See Troubleshooting Chart for corrective action.
Length of Cord
25 feet
50 feet
16
14
16
12
16
12
100 feet
10
10
10
7