ELECTRICAL
Electrical wiring should be performed by a qualified electrician, in accordance with all local electrical codes.
The pump should be on a dedicated (individual) circuit, controlled with a double pole switch (U.L./C-UL certified) rated at or above the fuse ampere indicated by the pump motor label. Depending on distance
of the power source from the pump and ampere load on the circuit, wire may need to be heavier than indicated by the chart.
All 115
and 230
pump motors and systems
VAC
VAC
Improper duty cycle and/or rapid start & stop conditions may cause the internal thermal breaker (if equipped) to trip, or can result in premature motor failure due to excessive heat. Refer
to the pumps Product Data Sheet.
For the pump to meet U.L./C-UL requirements the circuit MUST be protected with a slow-blow fuse (U.L./C-UL certified) or equivalent circuit breaker as indicated on the motor label. Use an approved wire of
the size specified or heavier.
CAUTION
Circuit protection is dependent on the
individual application requirements.
provide proper overload / thermal devices may result
in a motor failure, which will not be covered under
warranty.
TROUBLESHOOTING
Please Check the Following:
PUMP WILL NOT START
- Fuse or breaker
- For correct voltage (10%) and electrical connections
- Pressure switch operation and correct voltage
- Rectifier or motor for open or grounded circuit
- For locked drive assembly
- Internal thermal breaker (if equipped) tripped [Motor Hot]
WILL NOT PRIME (No discharge/Motor runs)
- Out of product
- Strainer for debris
- Inlet tubing/plumbing for severe vacuum leak
- Inlet/Outlet tubing severely restricted (kinked)
- Debris in pump inlet/outlet valves
- Proper voltage with the pump operating (10%)
- Pump housing for cracks
SERVICE KITS
Kits are readily available to repair standard 2088 series pumps. Repair kits include simple illustrated instructions allowing easy installation. To insure that the correct kit is received the model numbered and all
name plate data must be included with the order. Contact a SHURflo distributor or SHURflo directly to order the necessary repair kit.
1
Upper Housing Kit with Switch and Check Valve
2
Valve plate assembly
3
Diaphragm / Drive assembly
4
Motor
5
Complete Pump Head assembly (includes parts 1,2,3)
RETURN POLICY
All Industrial pumps/products must be flushed of any chemical (ref. OSHA Section 1910.1200 (d)(e)(f)(g)(h)) and hazardous chemicals must be labeled/tagged before being *shipped to SHURflo for service or warranty consideration.
SHURFLO reserves the right to request a Material Safety Data Sheet from the returnee for any pump/product it deems necessary. SHURFLO reserves the right to "disposition as scrap" pumps/products returned which
contain unknown fluids. SHURFLO reserves the right to charge the returnee for any and all costs incurred for chemical testing, and proper disposal of components containing unknown fluids. SHURFLO requests this in
order to protect the environment and personnel from the hazards of handling unknown fluids.
LIMITED WARRANTY PROCEDURE
SHURFLO warrants Industrial 2088 series pumps to be free from material and workmanship defects (under normal use and service) for a period of one (1) year from the date of manufacture, or (1) one year use with proof
of purchase, not to exceed (2) two years in any event.
The limited warranty will not apply to pumps that were improperly installed, misapplied, or incompatible with fluids or components not manufactured by SHURFLO. SHURFLO will not warrant any pump which is damaged
or modified outside the SHURFLO factory.
All Industrial pumps/products must be flush of any chemicals before *shipping. All warranty considerations are governed by SHURFLO's written Return Policy.
Returns are to be shipped postage prepaid to our service center in Elkhart, IN. SHURFLO shall not be liable for freight damage incurred during shipping. Package returns carefully. PENTAIR-SHURFLO, 52748 Park Six Ct.,
Elkhart, IN 46514.
Upon receiving a pump, it will be tested per SHURFLO's test criteria. SHURFLO's obligation under this warranty policy is limited to the repair or replacement of the unit. Pumps found not defective (under the terms of this
limited warranty) are subject to charges to be paid by the returnee for the testing and packaging of "tested good" units.
No credit or labor allowances will be given to the returnee for pumps returned as defective. Warranty replacements will be shipped on a freight allowed basis. SHURFLO reserves the right to choose the method of
transportation.
This limited warranty is in lieu of all other warranties, expressed or implied, and no other person is authorized to give any other warranty or assume obligation or liability on SHURFLO's behalf. SHURFLO shall not be liable
for any labor, damage or other expense, nor shall SHURFLO be liable for any indirect, incidental or consequential damages of any kind incurred by the reason of the use or sale of any defective product or part. This limited
warranty covers pumps distributed within the United States of America. Other world market areas should consult with the distributor for any deviation from this document.
* Carriers, including U.S.P.S., airlines, UPS, ground freight, etc., require specific identification of any hazardous materials being shipped. Check with your shipping company for specific instructions. Failure to do so may
result in substantial penalties.
SHURFLO
3545 Harbor Gateway South, Ste. 103, Costa Mesa, CA 92626, (800) 854-3218 www.shurflo.com
SHURFLO Europe, Middle East, Africa
Pentair Water Belgium bvba, Industriepark Wolfstee, Toekomstlaan 30, B-2200 Herentals, Belgium, +32-14-283500
All Pentair trademarks and logos are owned by Pentair, Inc. All other brand or product names are trademarks or registered marks of their respective owners.
Because we are continuously improving our products and services, Pentair reserves the right to change specifications without prior notice.
Pentair is an equal opportunity employer.
911-396 Rev R 12/14 ©Pentair, Inc. All rights Reserved.
be grounded per local and state electrical codes.
MUST
VOLTAGE
12 DC
24 DC
Failure to
36 DC
115 AC
BLACK (common) WHITE(neutral) GREEN (ground)
230 AC
BROWN (common) BLUE (neutral) GRN/YELL (ground)
2
1
WIRE LEADS
RED (positive +) BLACK (negative -)
LEAKS FROM PUMP HEAD OR SWITCH
- For loose screws at switch or pump head.
- Switch diaphragm ruptured or pinched
- For punctured diaphragm if fluid is present at bottom drain
PUMP WILL NOT SHUT-OFF (Pressure switch equipped)
- Output line closed and no leaks
- For air trapped in outlet line or pump head
- For correct voltage to pump (10%)
- Inlet/Outlet valves for debris or swelling
- Pressure switch operation/adjustment incorrect refer to Serv. Bulletin 1031
- For loose drive assembly or pump head screws
NOISY / ROUGH OPERATION
- Mounting feet that are compressed to tight
- Does the mounting surface multiply noise (flexible)
- For loose pump head or drive screws
- Is the pump plumbed with rigid pipe causing noise to transmit
4
3
5
WIRE SIZE
# 14 AWG [2.5 Mm 2 ] (or heavier)
# 16 AWG [1 Mm 2 ]
C-UL - TEW / UL 1015
2
[1 Mm
] C-UL - TEW / UL 1015
NOTE
Please have all pump information from
the data plate on the pump motor when calling
for service.
FUSE RATING
SEE PUMP MOTOR LABEL