MANUAL RESET
When the desk is used for the first time a reset must be done before you can operate the product. The reset causes all of the
columns to be brought to the same level. This ensures that the table top is positioned parallel with the ground. The controller
also saves the connected components in the standard configuration, such as columns or a sensor, if there is one attached. After
the reset, changes to the configuration are detected and considered to be errors. The system will not operate until the configura-
tion stored in its memory has been re-established.
When the actual desktop position no longer corresponds to the height displayed or you wish to use a configured control unit on
another identical electric height-adjustable desk, you have to reset the lowest desktop position to the minimum height.
1.
2.
3.
Danger: Intelligent system protection (ISP) is not enabled during all resets and limit position calibration.
Please note that there is a potential risk of pinching in this case.
Press the desktop down key.
Keep pressing it until the desktop has reached the lowest position
(programmed desktop position).
Press the desktop down key again and keep pressing it.
After about 5 seconds, the desktop will slowly move further down
until it reaches the absolutely lowest desktop position possible.
Release the desktop down key. The electric height-adjustable
desk can now be used again normally.
35