Press on the MENU
key again and you go
to:
5. Alarms
6
Load current display. It shows load current and battery
capacity.
Press MENU
to enter next display.
USB Voltage display. It shows the USB voltage
5V (2A max)
Press MENU
to enter next display.
Controller temperature display. If the controller
overheats it will automatic shut down and wait for the
temperature to drop to normal level and then it will start
again.
Press Press MENU
High temperature
When temp ≥ 85℃, the controller will enter into the first protection
phase: the PV input current will be lowered in order to reduce the
temperature. There is no alarm on the LCD display.
When temp >90℃, the controller will enter into the second
protection phase: the PV input current will be reduced to zero, the
load output will be switched off and a high temperature alarm
icon will show on the LCD.
After the temperature has decreased to less than 82℃, the
controller will resume normal operation.
10s and measure again to
make sure night falls. The
factory setting is 10sec
Short-circuit protection
setting.
Some inductive or capacitive
consumer will trigger the short-
circuit protection during start
up. Therefore the SC-
protection can be disabled
manually. Sc.F=OFF,
Sc.n=ON. The default is ON.
The factory setting is Sc.n.
to enter Main display.