DeFelsko PosiTest AT-A Manuel D'instructions page 9

Masquer les pouces Voir aussi pour PosiTest AT-A:
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

Cohesive and adhesive fractures are identified as follows:
Select Edit to set the number of layers
and cohesive/adhesive fracture details.
Use the
Upon completion of the pull-off test, the dolly and coated surface
should be examined. In addition to pull-off force, many National
and International standards such as ASTM D4541 and ISO 4624
require the nature of the fracture to be recorded.
Cohesive fracture:
fracture occurs within a coating
layer (same coating on dolly
face and coated surface).
Adhesive fracture:
fracture occurs at the interface
between layers (coating on
dolly face differs from surface).
buttons to adjust.
Analysis of Test Results
Dolly Face
8
Coated Surface

Publicité

Table des Matières
loading

Table des Matières