Connection to utilities (electrical connection)

The oven is supplied with a power cord without a plug. Connection to the electric network must be performed by interposing a
differential magneto-thermal switch with suitable characteristics, in which the minimum opening distance between the contacts
is at least 3 mm.
IN ADDITION, FOLLOW THESE INSTRUCTIONS:
The mains socket must be easily accessible and must not require any oven handling.
The electrical connection must be easily accessible even after oven installation.
The distance between the oven and the socket must be such that it does not cause the power cord to stretch.
Furthermore, the cable itself must not be under the base of the oven.
In order to avoid risks, any damaged power cord must be replaced by technical assistance service or a qualified
technician.

Grounding

The system MUST be grounded.
In compliance with current regulations, it is mandatory to connect the equipment to an equipotential system whose efficiency
must be correctly checked according to the regulations in force.
The connection is made on the special terminal located at the back of the oven, with a cable with a minimum section of
.
2
10mm
The terminal bears the following symbol:
69