Fl Ame Height; Blower Speed; Night Light Dimmer Control; In The Event Of A Power Failure - Napoleon Ascent Deep Serie Manuel Du Propriétaire

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

3.3
fl ame height
The remote control has six (6) fl ame levels. With the system on and the fl ame level at the maximum, press the
down arrow key once and it will reduce the fl ame height by one step until the fl ame is turned off.
The up arrow key will increase the fl ame height each time it is pressed. If the up arrow key is pressed while
the system is on but the fl ame is off, the fl ame will come on at the high position. A single "beep" will confi rm
reception of the command.
OFF
3.4

blower speed

The speed of the fan can be controlled by the remote
system. The fan speed can be adjusted through six (6)
speeds.
Use the mode key to guide you to the fan control icon.
Use the up/down arrow keys to turn on/off or adjust the fan
speed. A single "beep" will confi rm reception of the command.
note:
When the desired blower speed is selected, the blower will automatically come on 5 minutes after the main
burner has been turned on and remain on twelve minutes after it has been turned off.
3.5

night light dimmer control

ADD TITLE: Night Light Dimmer Control
The auxiliary function controls the Night Light™ with dimmable control.
A. Use the mode key to guide you to the Night Light™ icon.
B. The intensity of the output can be adjusted through 6 levels.
Use the up/down arrow keys to adjust the output level. A single beep
will confi rm reception of the command.
3.6

in the event of a power failure

If the receiver is equipped with batteries they will enable fl ame height control or on/off function to control the
appliance during a power failure. Blower and Night Light™ operation is not possible. Refer to "appliance
operation" section when communications between receiver and transmitter have been lost. The receiver will
emit a "beep" sound to confi rm programming has been successful once power is restored. During a power
failure, if the appliance was on, the fl ame height will stay at the setting prior to the failure. If off when the failure
occurs and then turned on, the fl ame height will come on at "Hi". The fl ame height can then be controlled by the
remote.
3.7

continuous pilot / intermittent pilot (CPI/IPI) selection

When the transmitter is in the off position, use the mode key to guide
you to the CPI mode icon.
Press the up/down to switch between IPI and CPI modes. A single
beep will confi rm reception of the command.
note:
If the appliance is equipped with a CPI/IPI* toggle switch, set the CPI/IPI
to CPI position to enable remote CPI operation. If the switch is set to IPI
then it will only work in IPI regardless of what is set on the remote control
handset.
* Some jurisdictions may prohibit the use of a standing pilot. In these jurisdictions, the CPI switch shall be
disconnected to comply with local code.
76
76
°F
Flame Off
Flame at level 1
remote control layout
76
°F
°F
Flame at level 5
Flame at "Hi" level 6
68
OFF
OFF
76
°F
Hi
76
76
°F
°F
Hi
76
76
°F
76
76
°F
IPI
CPI
W415-2913 / C / 09.21.20
EN
°F
°F
9

Publicité

Table des Matières
loading

Table des Matières