5.0 remote exterior installation
EN
5.1

remote exterior installation overview

WARNING
!
Minimum clearance to combustibles must be maintained or a serious fire hazard could result.
DO NOT cover or place any items in the Dynamic Heat Control™ air outlet opening. Failure to comply with
these instructions will create a fire hazard.
DHC™ Plus CANNOT be mounted directly above or below the appliance vent terminal as this will
cause the system to fail. It MUST be mounted to the left or right of the appliance vent terminal.
For optimal performance, we recommend installing DHC™ Plus within the top 12" (30.5cm) of the enclosure.
However, it MUST be installed above the appliance.
The minimum height requirement above the appliance will vary depending on the appliance size. See "minimum
venting requirements" section of your appliance manual for details.
DHC™ Plus remote exterior installation can be installed remotely from the appliance enclosure up to 60' (18.2m)
away.
Required:
DHCP-BK
DHCP-EK
Venting, 6" rigid steel (not supplied)
note:
MUST have air outlet opening.
Appliance Vent
Enclosure
Appliance
note:
Diagram is for illustrative purposes only. Installation must comply with all local codes.
14
W415-1789 / C / 01.29.19
Blower
Housing
Assembly
Terminal (if
Air
applicable)
Damper
Assembly
Collar Plate
Assembly
6" Rigid Steel
Venting (not
supplied)
Inside View
of Bulkhead
Exterior
(Some Framing and
Finishing Hidden
for Clarity)
Maintain
distance to
combustibles.
Interior
Exterior Housing
Assembly
View of Opposite
Exterior Wall
Wall
Flashing
Insulation
Decorative
Cover