Programming Table for Measuring Range
Pulse frequency 0 ... f
Measuring configuration
Tube
Tube
nomi-
internal
nal
dia-
width
meter
DN
[mm]
25
28.5
40
39.3
40
43.1
40
45.8
50
51.2
50
54.5
50
57.5
50
64.2
65
70.3
65
76.1
80
82.5
100
100.8
100
107.1
125
125.0
125
131.7
150
150.0
150
159.3
150
182.5
NOTE
If the decimal-point digit number D
contrast to the preset table values, then the scaling factor S
must be set to the 10-times value. In this case, the overflow
duration will inevitably be reduced to 1/10 of the table value.
= 100 Hz
max
Max.
Overflow
flow
duration
rate
at max.
flow rate
[Nl/min]
[days]
305
2279
544
1276
663
1048
754
921 0.0126
954
728
1085
640
1211
574
1519
457
1831
379
2161
3213
2556
2717
3850
1804
4357
1594
5979
1162
6653
1044
8663
802
9806
708
12949
536
w
= 0 ... 10 m/s
N
Programming input
S
M
K
(Line
(Line
no.
no.
22)
23)
0.0051
0.0091
0.0110
0.0159
0.0181
0.0202
0.0253
0.0305
0.0036
0.0043
0.0064
0.0073
0.0100
0.0111
0.0144
0.0163
0.0216
is increased by 1, in
P
24
D
I
P
M
(Line
(Line
no.
no.
28)
37)
90
2
1772.35
90
2
991.90
90
2
814.90
90
2
715.97
90
2
566.23
90
2
497.80
90
2
446.06
90
2
355.53
90
2
295.00
90
1
249.84
90
1
211.24
90
1
140.27
90
1
123.95
90
1
90.32
90
1
81.16
90
1
62.34
90
1
55.07
90
1
41.70
K