Installation and Location

When pool equipment is located below the pool surface, a leak from any component can cause large
scale water loss or flooding. Pentair cannot be responsible for such water loss or flooding which may
cause damage to the product. Avoid placing the heat pump in locations where it can cause damage by
water or condensate leakage. If this is not possible, provide a suitable drain pan to catch and divert any leakage.
Only a qualified service person should install the heat pump. Before installing this product, refer to the
Important Warning and Safety Instructions
Packaging
This appliance must be packed and stored vertically, as specified on the packing.
A horizontal storage, even if temporary, will damage the appliance.
All damage due to incorrect packing or storage,will not be taken under warranty
Pentair encourages its customers to keep the heat pump packaging (paperboard pack +
polystyrene + pallet) for the duration of the warranty period in case of a need to return the
appliance to the factory.
The manual, unions and anti-vibration spacers are packed underneath the top cover.
Materials Needed for Installation
The following items are needed and are to be supplied by the installer for all heat pump installations:
1.
Plumbing connections (50mm).
2.
Level surface for proper drainage.
3.
Suitable electrical supply line. See rating plate on unit for electrical specifications. A junction box is not needed at
the heat pump; connections are made inside of the heat pump electrical compartment.
Installation location
Respect safety distance between the pool and the heatpump (electric appliance) as required by
local regulation
Maintain at least 1 m (40 ") of space on the rear (evaporator air inlet ) and 3m (120 ") on the outlet side of the fan on
a completely free space. Make sure that the
discharged air will not be sucked back into the
evaporator again.
1. Provide enough space to allow access to
temperature controller.
2. For proper drainage of condensation and rain
water, place the heat pump on a flat slightly
pitched surface, such as a concrete or
fabricated slab (pad).
3. If possible, place the pad at the same level or
slightly higher than the filter system
equipment pad.
4. Note: Be sure that the pad is pitched not more
than 1% in any direction as needed for runoff.
5. Mark the 4 fixation point on the equipment
pad (It is also possible to use the template
printed on the box)
6. Drill adequate holes for the fixation screws or anchor bolts. These screws should be at least 6mm diameter and
made of a corrosion resistant material.
7. Mount the heatpump on the rubber pads over the fixation holes.
8. Tighten the screws.
6
UltraTemp®-E
1 m
3 m
1 m
1 m