Operator Set Up Menu Tree Guide (Press UP and DOWN Arrows Simultaneously)
Navigating the Operator Set Up Screen
Press the Up and Down arrows simultaneously. If no activity is detected after 15 seconds, the display will return to the
main screen. Press the MENU SELECT button to view each screen
LANGUAGE/IDIOMA
SELECTED-
SOFTWARE VERSION
474788.BC
PUMP START TIME
TIME=
INTELL ADDRESS
ADDRESS=
START DELAY
TIME=
TEMP SCALE
FAHRENHEIT
WATERTEMP OFFSET
OFFSET=
DEFROST
ENABLED
AUTOSET
DISABLED
EXTEND
DISABLED
WF HP LP PL SP
1
1
1
FAN COMP PMP REV
0
1
RUN TIMES/COUNTS
↑ OR ↓ TO VIEW
PRESS POOL/SPA
TO EXIT SETUP
ENGLISH
2 HRS
1
1 MIN
-2 C
0
0
0
1
1. Language
Select between English, French, German, Dutch, Spanish or
Italian.
2. Software Revision Displays the software revision level
loaded on the control board.
3. Pump Start Time This displays the period at which the
heat pump will close the AutoSet contactor to start the filter
pump. Adjustable from 0 to 5 hours using the UP and DOWN
arrows.
4. Intelli Address IntelliPool
Address Should always be set to 1
5. Temperature Scale Determines if the water temperature
actual reading and set point is displayed in degrees
Fahrenheit or Celsius. Adjusted between Fahrenheit and
Celsius using the UP and DOWN arrows.
6. Watertemp Offset
temperature up or down to allow the operator to match the
heat pump measured temperature to a remote temperature
monitoring device. The offset can be varied from -2 to +2
using the UP and DOWN arrows.
7. Defrost Screen Allows to Enable/Disable defrost cycle
using the UP and DOWN arrows
8. Autoset Allows to Enable/Disable the Autoset Function
using the UP and DOWN arrows
9. Extend Allows to Enable/Disable the Extend Function
using the UP and DOWN arrows
10. Input Screen The Input screen is a diagnostic display
which shows the status of the input sensors. The number 1 is
displayed when the associated input is on and zero is
displayed when the associated input is off. WF= Flowswitch,
HP = High pressure LP= Low pressure, PL= Pool remote and
SP = Spa remote
11. Output Screen The Output screen is a diagnostic display
which shows the status of the Output devices.The number 1
is displayed when the associated output is on and zero is
displayed when the associated output is off. FAN= Fan,
COMP= compressor, PMP= pump relay, REV= reversing valve
12. Run Times / Counters screen Use the up and down
arrow to scroll through an extensive list of log times and
counters for the main components of this heatpump. For
each of the outputs as well as the defrost function run times
and number of run cycles can be retrieved. The menu also
allows for a reset of the timers and counters. The 'warranty'
times and counters cannot be reset and represent the heat
pumps total lifetime values
13. Exit Set Up Pressing the POOL/SPA button while this
screen is displayed returns the display to the Pool or Spa Run
Screen as appropriate.
®